6515--NX EQ Lift: Patient Transfer: Clip Based Standard
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
DESCRIPTION
The Veterans Health Administration (VHA) Non-Expendable Equipment National Program has identified the Lifts: Patient Transfer: Clip Based Standard product line as a candidate for a VA-wide (otherwise referred to as national ) single Requirements contract award.
The Department of Veterans Affairs (DVA) Office of Procurement, Acquisition and Logistics (OPAL) Strategic Acquisition Center (SAC) on behalf of VHA is issuing this Sources Sought Notice in accordance with the FAR 10.002(b)(2) to determine the availability and technical capabilities of qualified sources.
The SAC in conjunction with VHA is seeking a qualified source to provide Arjo Maxi Move® brand name or equal the Lifts: Patient Transfer: Clip Based Standard on an agency wide basis. VA intends to award a Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver the Lifts: Patient Transfer: Clip Based Standard to VA medical centers and facilities throughout the United States and its territories.
The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need. The Contractor must demonstrate the ability to meet all requirements for the solicitation.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339113- Surgical Appliance and Supplies Manufacturing, Product Service Code: 6515 Medical and Surgical Instruments, Equipment, and Supplies and the associated size standard is 800 employees. The FAR Provision found at 52.204-7(b)(1) requires that All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of proposal submission.
Submissions for this source sought shall be submitted by email no later than September 8th, 2025, at 10:00am EST to all the following:
Jalima.Jones@va.gov
Sara.Vickroy@va.gov
This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes.
2.0 SCOPE
Lifts: Patient: Transfer: Clip Based Standard are designed for hoisting and transferring a patient safely and with minimal physical effort. These lifts consist of a C-shaped or U-shaped support base usually including casters, a vertical mast, a pivoting boom, a swivel bar, a hanger bar or spreader bar with hooks to accommodate loop-based slings, and the lifting mechanism; they are manually, electrically, or battery operated using hydraulic or screw jack lifting mechanisms. Patient lifts are frequently used to transfer patients (e.g., to and from a wheelchair, toilet, or bathtub), reducing the risk of injury to those assisting with the transfer (typically only one person) and of patient drop.
The following Contract Line-Items Number (CLIN) are being considered:
CLIN
Manufacturer
Part Number
Description
0001
Arjo
KMEHE0-0-0-01
600 lbs SWL, X-Low Base
0002
Arjo
KMEHE0-0-D-01
600 lbs SWL, X-Low Base, Med-PDPS
0003
Arjo
KMEHE0-M-0-01
600 lbs SWL, X-Low Base, Motion Assist
0004
Arjo
KMEHE0-M-D-01
600 lbs SWL, X-Low Base, Med-PDPS, Motion Assist
0005
Arjo
KMEHEU-0-0-01
600 lbs SWL, X-Low Base, Scale
0006
Arjo
KMEHEU-0-D-01
600 lbs SWL, X-Low Base, Scale, Med-PDPS
0007
Arjo
KMEHEU-M-0-01
600 lbs SWL, X-Low Base, Scale, Motion Assist
0008
Arjo
KMEHEU-M-D-01
600 lbs SWL, X-Low Base, Scale, Med-PDPS, Motion Assist
0009
Arjo
KMEHL0-0-0-01
600 lbs SWL, Low Base
0010
Arjo
KMEHL0-0-D-01
600 lbs SWL, Low Base, Med-PDPS
0011
Arjo
KMEHL0-M-0-01
600 lbs SWL, Low Base, Motion Assist
0012
Arjo
KMEHL0-M-D-01
600 lbs SWL, Low Base, Med-PDPS, Motion Assist
0013
Arjo
KMEHLU-0-0-01
600 lbs SWL, Low Base, Scale
0014
Arjo
KMEHLU-0-D-01
600 lbs SWL, Low Base, Scale, Med-PDPS
0015
Arjo
KMEHLU-M-0-01
600 lbs SWL, Low Base, Scale, Motion Assist
0016
Arjo
KMEHLU-M-D-01
600 lbs SWL, Low Base, Scale, Med-PDPS, Motion Assist
0017
Arjo
700-34267-BOX
POWERED DPS COMBI MEDIUM
0018
Arjo
700-34271-BOX
POWERED DPS COMBI LARGE
0019
Arjo
MFA1000M-S-L1
DISPOSABLE CLIP SLING, SMALL
0020
Arjo
MFA1000M-M-L1
DISPOSABLE CLIP SLING, MEDIUM
0021
Arjo
MFA1000M-L-L1
DISPOSABLE CLIP SLING, LARGE
0022
Arjo
MFA1000M-XL-L1
DISPOSABLE CLIP SLING, X-LARGE
0023
Arjo
MFA1000M-XXL-L1
DISPOSABLE CLIP SLING, XX-LARGE
0024
Arjo
MFA2100-S-L1
DISPOSABLE LOOP SLING, SMALL
0025
Arjo
MFA2100-M-L1
DISPOSABLE LOOP SLING, MEDIUM
0026
Arjo
MFA2100-L-L1
DISPOSABLE LOOP SLING, LARGE
0027
Arjo
MFA2100-XL-L1
DISPOSABLE LOOP SLING, X-LARGE
0028
Arjo
MFA2100-XXL-L1
DISPOSABLE LOOP SLING, XX-LARGE
0029
Arjo
MAA4000M-S-L1
LAUNDERABLE CLIP SLING, SMALL
0030
Arjo
MAA4000M-M-L1
LAUNDERABLE CLIP SLING, MEDIUM
0031
Arjo
MAA4000M-L-L1
LAUNDERABLE CLIP SLING, LARGE
0032
Arjo
MAA4000M-XL-L1
LAUNDERABLE CLIP SLING, X-LARGE
0033
Arjo
MAA4000M-XXL-L1
LAUNDERABLE CLIP SLING, XX-LARGE
0034
Arjo
MLA2000-S-L1
LAUNDERABLE LOOP SLING, SMALL
0035
Arjo
MLA2000-M-L1
LAUNDERABLE LOOP SLING, MEDIUM
0036
Arjo
MLA2000-L-L1
LAUNDERABLE LOOP SLING, LARGE
0037
Arjo
MLA2000-XL-L1
LAUNDERABLE LOOP SLING, X-LARGE
The Department of Veterans Affairs (VA) is seeking vendors who can provide Arjo Maxi Move® brand name or equal Lifts: Patient Transfer: Clip Based Standard as listed above or equal commodities which meet all the following salient characteristics (SCs):
CLINs 0001-0016 apply to the following SCs
SC #
SALIENT CHARACTERISTICS
METHOD OF EVALUATION
SC 1
Lift must be allowed to be used with repositioning, turning, and limb lifting slings with at least one style of hanger bar.
Literature Review
SC 2
Clip based hanger bar with powered positioning to tilt a patient while lifted to keep the patient in a safe level position.
Literature Review
SC 3
Weight capacity that accommodates patients weighing 500 lbs. or greater.
Literature Review
SC 4
Options for multiple wheel heights, including an option of a low base that allows passage under a stretcher with a 2.5-inch clearance and an option of 3-inch wheels or larger.
Literature Review
SC 5
Low battery indicator.
Literature Review
SC 6
Lifting range that allows floor rescue of patients and lifting to high surfaces (hanger bar can reach 16 inches or lower and 60 inches or higher).
Literature Review
SC 7
Legs adjustable to a minimum interior width of 40.1 inches.
Literature Review
SC 8
Raising/lowering mechanism that keeps the patient at the same distance from the mast regardless of height.
Literature Review
SC 9
Legs widen and narrow electrically using a control button.
Literature Review
SC 10
Lift must be allowed to be used for ambulation.
Literature Review
SC 11
Option to charge using a second battery and a wall charger.
Literature Review
SC 12
Lift must be tested in accordance with ISO 10535:2021.
Literature Review
SC 13
Lifting must be motorized.
Literature Review
SC 14
Lift must provide emergency stop and manual emergency lowering.
Literature Review
SC 15
Max exterior width with legs closed 30 inches
Literature Review
For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics specified above.
The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the Original Equipment Manufacturer and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.
Responses to this Sources Sought Notice shall include the following:
Does vendor offer an annual service plan, Yes or No?
If Yes:
What does the plan cover?
Does plan cover software updates only?
Does the plan cover parts repair or replacement only?
Does the plan cover both software and parts?
Vendor are requested to provide documentation that shows information on their service plan.
Is the service provided by the OEM or a subcontractor?
Full name and address of company
DUNS number/ CAGE Code/ SAM UIE
Business Size
Manufacturer or Distributor
If distributor provide full name, business size and address of manufacturer.
Country of Origin designation for all products
Ability to provide uninterrupted supply of products on a national scale.
Technical Literature that clearly shows product(s) meet the identified salient characteristics and page numbers where each salient characteristic is met.
Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
Authorized Distributor Letter Certified by OEM with a current date.
Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.