6515--RFI 36C26226Q0937 VALL Viasonix Falcon Pro OR EQUAL Physiologic Vascular Testing System

SOL #: 36C26226Q0937Sources Sought

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
262-NETWORK CONTRACT OFFICE 22 (36C262)
Gilbert, AZ, 85297, United States

Place of Performance

Place of performance not available

NAICS

Surgical and Medical Instrument Manufacturing (339112)

PSC

Medical And Surgical Instruments, Equipment, And Supplies (6515)

Set Aside

No set aside specified

Timeline

1
Posted
Jun 9, 2026
2
Response Deadline
Jun 23, 2026, 3:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VA) is conducting a Request for Information (RFI) / Sources Sought to identify qualified vendors for a Viasonix Falcon Pro OR EQUAL Physiologic Vascular Testing System for the VA Medical Center in Loma Linda, CA. This is for market research purposes only and does not constitute a solicitation. Responses are due by Tuesday, June 23, 2026, at 8:00 AM Pacific Time (PT).

Scope of Work

The VA seeks a Physiologic Vascular Testing System that meets or exceeds the specified salient characteristics, including at least 10 independent pressure channels, 5 independent PPG sensors, 10MHz Doppler probe, quick ABI/TBI measurement, user-friendly interface, high-quality spectral Doppler, DICOM compatibility, and PVR capability with more than two cuffs simultaneously. The contractor will be responsible for delivery, installation, on-site in-service, and end-user training. A standard manufacturer's warranty is required. The vendor must also handle offloading, uncrating, setup, and waste removal.

Contract & Timeline

  • Opportunity Type: Sources Sought / Request for Information (RFI)
  • NAICS Code: 339112 – Surgical and Medical Instrument Manufacturing (respondents may suggest alternatives).
  • Response Due: June 23, 2026, 8:00 AM PT
  • Published Date: June 9, 2026
  • Place of Delivery: VA Loma Linda Healthcare System, 11201 Benton Street, Loma Linda, CA 92357-1000.

Submission Requirements

Interested and capable contractors must submit the following via email to Dyne.Kim@va.gov:

  • Company name, address, point of contact, phone, fax, and email.
  • Unique Entity ID (SAM) number.
  • Type of small business (e.g., SDVOSB, VOSB, 8(a), HUB-Zone, WOSB, SDB, Small Business) and statement on meeting NAICS size standard.
  • Brand name, model, and product description of the proposed system, including country of origin and manufacturer's small business status.
  • Statement on Buy American Statute/Trade Agreement applicability.
  • Authorization to distribute the product (if applicable), including details if the firm exceeds 500 employees, is primarily engaged in retail/wholesale, takes ownership, or supplies small business manufactured items.
  • Information on existing GSA FSS, VA NAC, NASA SEWP, or other federal contracts for the product.
  • Estimated delivery time (ARO).
  • General pricing for the proposed system.
  • Documented self-attestation/certification of FDA compliance.
  • A detailed capability statement with at least one reference contract demonstrating experience providing the specified system, including legal name of entity, contract number, specific tasks performed, dates, and verifiable contact information.

Important Notes

This RFI is for market research only; it is not a solicitation, and responses do not form a binding contract. All offerors must be registered in SAM.gov with current Representations and Certifications. Only new equipment from an OEM, authorized dealer, distributor, or reseller will be accepted; gray market or remanufactured items are not acceptable. All expenses associated with responding are the responsibility of the responder. Responses will help the government determine potential set-aside opportunities.

People

Points of Contact

dyne.kim@va.govDyne KimPRIMARY

Files

Files

Download
Download

Versions

Version 1Viewing
Sources Sought