6640--Volcano Intrasight Philips

SOL #: 36C25726Q0160Sources Sought

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
257-NETWORK CONTRACT OFFICE 17 (36C257)
San Antonio, TX, 78240, United States

Place of Performance

Place of performance not available

NAICS

Surgical Appliance and Supplies Manufacturing (339113)

PSC

Laboratory Equipment And Supplies (6640)

Set Aside

No set aside specified

Timeline

1
Posted
Dec 9, 2025
2
Last Updated
Jan 12, 2026
3
Response Deadline
Dec 12, 2025, 9:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Page 7 of 7

Page 1 of

This market research notice is being conducted by Network Contracting Office (NCO) 17- VA Central Texas (VACTHCS) facilities.

The AVAMC (Amarillo VA Medical Center) requires a brand name or equal Philips Intrasight Mobile 5/Volcano. The Philips Volcano will attach to the GE Mac-Lab system in the CathLab which is currently being built. This piece will allow the Physician to be able to see the amount of blockage there is at any point in the artery. This will enable AVAMC to do interventional heart studies for the local Veterans, so they don t need to travel to another facility to get this care.

1. SERVICES:

This will include all pieces of the system needed to perform a Cardiac Catheterization, Stent Placement, Calculation of Blockage and other Interventional Studies. All installations shall follow the guidelines of The Joint Commission, NFPA, CDRH, VAMC. All work will Take place during normal business hours of 8-5, unless prior arrangements have been agreed upon. There will be no work conducted on any Government Holiday or after hours unless there is mutual Agreement between the COR and the installation team of Philips. All work must be Turn-key from the vendor.

Salient Characteristics:

Combined modalities on a single platform to provide a comprehensive view of the targeted vessel, these include:

Intravascular Ultrasound (IVUS) which provides detailed images of the vessel s interior to assess size, lesions, or plaques.

Instantaneous Wave Free Ratio (iFR) and Fractional Flow Reserve (FFR) which measure blood flow and pressure within vessels to evaluate significance of a blockage.

Angiography co-registration which integrates iFR and IVUS data with an angiogram, allowing the physician to map real-time pressure profiles and vessel measurements directly onto the x-ray image.

Integration with GE and/or Philips therapy systems to reduce data entry errors

9.7 diagonal monitor

1 CPU processor with 2/3 GHz

DICOM compatible

Windows 10 operating system

The following is the equipment to be installed:

Volcano/Intrasight Mobile 5 With Cart

Performance Monitoring

Clinical Engineering will monitor the install to ensure everything is being installed as planned, timely, and that will be done by the Government s appointee.

Place of Performance.

The Place of performance will be located at 6010 Amarillo Blvd West, Amarillo, Texas 79106, BLDG 1, 4th Floor.

Responses shall include:

Business Name

Business Address

Point of Contact

Name

Phone Number

E-mail Address

SAM UID Number

Currently registered in SAM (Yes or No). If Yes, provide expiration date.

NAICS code

Business Size: Small or Large

Type of Business: Service-Disabled Veteran Owned (SDVOSB), Veteran Owned (VOSB), 8(a), HUBZone, Woman-Owned (WOSB), etc.

GSA or VA FSS Contract Number, if applicable

Please include Authorization Letter from Philips Healthcare Solutions indicating that Vendor has all certifying personnel and authorization to supply this specific equipment.

All businesses eligible to provide this service are encouraged to reply as this information may be used to determine potential set-asides for the above-noted requirement.

Send responses to both the Contract Specialist and the Contracting Officer.

Contract Specialist: Mr. Rafael Rodriguez at

Rafael.Rodriguez2@va.gov

Responses in the email subject line shall state: 36C25726Q0160 , Sources Sought Notice

Responses due date: 12/12/2025- 3PM CT

DISCLAIMER: This notice is issued solely for informational and planning purposes and does not constitute a solicitation. Responses to this notice are not offers and cannot be accepted by the Department of Veterans Affairs to form a binding contract. Respondents are solely responsible for all expenses associated with responding to this notice.

People

Points of Contact

Rafael RodriguezContracting OfficerPRIMARY

Files

Files

Download

Versions

Version 3
Solicitation
Posted: Jan 12, 2026
View
Version 2
Pre-Solicitation
Posted: Jan 12, 2026
View
Version 1Viewing
Sources Sought
Posted: Dec 9, 2025