B112 Compressor Replacement

SOL #: W50S8S26QA004Solicitation

Overview

Buyer

DEPT OF DEFENSE
Dept Of The Army
W7NU USPFO ACTIVITY OHANG 180
SWANTON, OH, 43558-9645, United States

Place of Performance

Swanton, OH

NAICS

Air and Gas Compressor Manufacturing (333912)

PSC

Compressors And Vacuum Pumps (4310)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Apr 13, 2026
2
Submission Deadline
May 12, 2026, 2:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of the Army, specifically the W7NU USPFO ACTIVITY OHANG 180, is soliciting proposals for the B112 Compressor Replacement project in Swanton, OH. This Total Small Business Set-Aside requires contractors to provide all necessary personnel, equipment, tools, materials, supervision, and quality control to replace the existing air compressor in Building 112. The acquisition is a Firm Fixed Price contract under NAICS code 333912 (Compressors And Vacuum Pumps) with a 1000-employee size standard. Proposals are due by May 12, 2026, at 2:00 PM Z.

Scope of Work

The contractor shall remove and dispose of the existing air compressor and associated air drier in Building 112. The project includes purchasing and installing a new dual-head air compressor and drier system capable of a minimum of 75 SCFM at 100 PSI, with the ability to reach a minimum of 175 PSI. The new system must be relocated to the electrical/mechanical room, requiring all necessary piping, electrical connections (3 PH 480V), and equipment to ensure full operational capability. This also involves removing and capping unrequired components from the old system.

Performance Standards

Key performance metrics include:

  • Minimum 75 SCFM output at 100 PSI continuous operation.
  • Capability to reach a minimum 175 PSI maximum pressure.
  • Dual-head configuration.
  • All electrical work compliant with NEC standards and local codes, with zero electrical deficiencies.
  • Leak-free connections with proper pressure ratings and code compliance, with zero leaks at operating pressure.
  • Fully operational system meeting all performance requirements upon project completion.
  • 100% of existing equipment removed and properly disposed of.

Contract Details

  • Contract Type: Solicitation (Firm Fixed Price)
  • Set-Aside: Total Small Business Set-Aside (FAR 19.5)
  • NAICS: 333912 (Compressors And Vacuum Pumps), Size Standard: 1000 employees
  • Period of Performance: 60 days after contract award date.
  • Place of Performance: Building 112, 180th Fighter Wing, 2660 S. Eber Rd., Swanton, OH 43558.
  • Work Hours: Monday through Friday, 0700 - 1600, excluding recognized US holidays.
  • Payment: Via Wide Area WorkFlow (WAWF) as per DFARS 252.232-7006.

Special Requirements & Notes

Contractors must develop and maintain an effective Quality Control (QC) Plan, comply with installation access and security policies, and ensure personnel obtain base identification and complete Antiterrorism Awareness Level I Training. Submittals include cut sheets, an Ozone Depleting Substances Form, as-built drawings, O&M manuals, and AF Form 3000. A burn permit is required for open flame or spark-producing work. Item unique identification and serialization requirements (DFARS 252.211-7003) are applicable. The solicitation incorporates various FAR and DFARS clauses by reference.

Visual References

Several image documents are provided, including a picture of the existing compressor, and images of various electrical panels (B112 Panel MCC, L1, L2, L1 Spare 70A, EP) to aid bidders in understanding the current site conditions and electrical infrastructure.

People

Points of Contact

TSgt Cody WalkerPRIMARY
MSgt Scott HartzellSECONDARY

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download

Versions