BAS Compressor Repair
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Centers for Disease Control and Prevention (CDC), specifically the National Institute for Occupational Safety and Health (NIOSH), is seeking services for BAS Compressor Repair in Pittsburgh, PA. This procurement is for the repair of a critical Bauer breathing air compressor. Quotes are due May 26, 2026, at 12:00 PM EST.
Purpose & Scope
The purpose of this contract is to repair the NIOSH-owned Bauer breathing air compressor (m/n VTC-7K/20, s/n 233012) to full operational status. This compressor is essential for respirator approval and audit testing, including CBRN, SCBA, and Firefighting respirators, which require high-pressure breathable air. The scope is limited to the parts and labor required for this repair, located in B40 on the NIOSH Pittsburgh campus.
Key Requirements & Deliverables
- Full repair of the Bauer breathing air compressor (m/n VTC-7K/20, s/n 233012).
- Includes all necessary parts and labor.
- Specific components to be replaced:
83493-EU FILTER CHAMBER 550BAR (BKM),083544 SEP,OIL/WATER;COALESC,550BAR, andN17066-517 VAL,SAFETY;517BAR,RP1/2"M. - Service must be completed within six months of contract award.
- A service report is required within one week of completed calibration.
Contract Details
- Type: Solicitation (RFQ), suggesting a Firm-Fixed-Price contract.
- Period of Performance: On or before June 1, 2026.
- Set-Aside: Not a small business set-aside. Limited to the original manufacturer's required parts and service vendor (Breathing Air Systems for Bauer).
Submission & Evaluation
- Quotes Due: May 26, 2026, at 12:00 PM EST.
- Submission: To Paula Taylor at
VGA8@CDC.gov. - Evaluation: Criteria are not detailed in the provided document.
Additional Notes
- The government will provide a secure, partially temperature-controlled facility for the work.
- Typical working hours are 9:00 AM to 3:30 PM.
- Contract shall include all costs for vendor travel to Pittsburgh, PA.
- Various FAR and CDCH clauses are incorporated by reference.