Demolition of Cavity Wall complete with labor and material
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The U.S. Department of State, specifically the U.S. Embassy New Delhi, has issued an Amendment (A001) to solicitation 191N6526Q0026 for the Demolition of Cavity Wall complete with labor and material in New Delhi, India. This amendment provides crucial clarifications and updates based on discussions during a contractor's walk-through. The response date remains April 9, 2026, at 6:00 PM Z. This is a Special Notice related to demolition services.
Scope of Work
This amendment details the contractor's responsibilities for demolition, protection, site access, and equipment. Key aspects include:
- Demolition Scope: Removal of walls, services (toilets only), and disposal of all demolition fixtures. Doors with frames must be removed and returned to the USG. Wardrobe removal and disposal are also required.
- Protection Measures: Contractors must protect the entire second floor, newly laid ground floor, balcony railing, and new floors from debris and during material hauling. Dust protection is mandatory.
- Site Access & Interruption: The ground floor will host events, requiring contractors to accommodate weekly interruptions of approximately four hours.
- Utilities & Equipment: Contractors must provide their own portable toilet connected to the existing sanitary line and maintain cleanliness. Hydraulic jacks are necessary for the initial demolition phase.
- Service Protection: Existing bathroom services (sanitary and wastewater drainage) and ducts running through walls must be protected.
- Restrictions: Heavy hammering or vibration-producing activities are strictly prohibited.
- Area Specifications: Specific dimensions are noted for low-height corridor ceilings (450 sq ft) and low-height bathroom ceilings (400 sq ft).
Contract & Timeline
- Type: Special Notice (Amendment to Solicitation 191N6526Q0026)
- Product/Service Code: P400 (Demolition Of Buildings)
- Set-Aside: None specified
- Response Due: April 9, 2026, 6:00 PM Z
- Published Date: April 7, 2026
- Amendment Effective Date: April 7, 2026
Additional Notes
This amendment does not extend the deadline for offers. Contractors are required to acknowledge receipt of this amendment with their submission. For inquiries, contact Chaitanya Sharma, Procurement Supervisor (sharmac@state.gov) or Sudhir P. Kamath (kamathsp@state.gov).