DQCA, Commercial Diesel Generator Set, 600kW Standby 60Hz
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
DQCA, Commercial Diesel Generator Set, 600kW Standby 60Hz, 600DQCA, Diesel Genset, 60Hz, 600kW, Duty Rating - Standby Power (ESP), Emission Certification, EPA, Tier 2, NSPS CI Stationary Emergency, Listing - UL 2200, Voltage - 277/480, 3 Phase, Wye, 4 Wire, Alternator - 60Hz, Wye, 480 Volts, 105C ? Standby, Alternator Heater, 120 Volt AC, Steel Sound Attenuated Level 2 Enclosure, with Exhaust System, Enclosure Color - Green, Steel, Cooling Air Outlet - Horizontal, Sound Attenuated, Louvers - Air Inlet, 24 Volts DC Spring Closed, Motor Opened, Louvers - Air Outlet, 24 Volts DC Spring Closed, Motor Opened, Distribution Panel - Prewired AC Features, Fuel Tank - Sub Base, 2400 Gallon, UL142 Compliant, Listing, ULC - S601 ? 07, Alarm - High Fuel Fill, Fuel Tank Connection - Dual Stub Up, Fuel Water Separator, Control Mounting - Left Facing, Power Command 2.3 Controller, LCD Control Display, Stop Switch - Emergency, Externally Mounted, Signals - Auxiliary, 8 Inputs/8 Outputs, Control Display Language ? English, Circuit Breaker or Entrance Box or Terminal Box - Right Only, Terminal Box- Low Voltage, Left- None, Circuit Breaker - 1200A, Right, 3P, UL 600, IEC 415, UL Serv Ent, 100%, Circuit Breaker or Entrance Box or Terminal Box, Top Entry, Left- None, Bottom Entry, Right, Engine Air Cleaner - Normal Duty, External Battery Charger - 12 Amp, Regulated, Engine Cooling - Radiator, 50C Ambient, Shutdown - Low Coolant Level, Coolant Heater - 208/240/480 Volts AC, Below 40F Ambient Temperature, Genset Warranty - 2 Years Base, Literature ? English, Packing - None, Base Mounted Housing, OTECD, OTEC Transfer Switch- Electronic Control: 800A/1000A, OTEC1000, Transfer Switch, Power Command, 1000 Amp, Listing - UL 1008/CSA Certification, Application - Utility to Genset, Cabinet - Type 1, Poles - 3 (Solid Neutral), Frequency - 60 Hz, System - 3 Phase, 3 or 4 Wire, Voltage - 480 Volts AC, Genset Starting Battery - 24V DC, PC40 Control, Auxiliary Relay - 24 Volts DC Coil, Auxiliary Relay - Switch in Emergency Position - 24 Volts DC, Interface - Communications Network, MODBUS RTU Module, Transfer Switch Warranty - 1 Year Comprehensive