DSCR B3 Roof Vent Repair

SOL #: SP470326Q0041Combined Synopsis/Solicitation

Overview

Buyer

DEPT OF DEFENSE
Defense Logistics Agency
DCSO RICHMOND DIVISION #1
RICHMOND, VA, 23237, United States

Place of Performance

Richmond, VA

NAICS

Commercial and Institutional Building Construction (236220)

PSC

Repair Or Alteration Of Other Warehouse Buildings (Z2GZ)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
May 11, 2026
2
Submission Deadline
Jun 13, 2026, 3:59 AM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Defense Logistics Agency (DLA), specifically DCSO Richmond Division #1, is soliciting proposals for DSCR B3 Roof Vent Repair at the Defense Supply Center Richmond, VA. This is a Combined Synopsis/Solicitation (RFQ SP4703-26-Q-0041) for commercial services to repair a large metal roof vent and associated roof damage. This acquisition is a Total Small Business Set-Aside. The resulting contract will be a Firm Fixed-Price (FFP) award. Proposals are due June 12, 2026, at 11:59 PM EST.

Scope of Work

The contractor will be responsible for the complete removal and disposal of an existing large metal roof vent from Building 3. The scope includes comprehensive roof repair, which involves installing new rafters and supporting components, enclosing the roof opening with 5/8" plywood, applying 15# felt paper, and installing 3-tab shingles that match the existing color and exposure. Interior work entails framing the ceiling opening with 20-gauge steel studs, installing 5/8" mold-resistant gypsum wallboard, finishing the new wallboard to Level 4, and applying two coats of white flat paint. Additionally, the contractor must provide a portable toilet for the duration of the project.

Contract Details

  • Contract Type: Firm Fixed-Price (FFP)
  • Period of Performance: 60 days from the Notice to Proceed.
  • Estimated Magnitude: Less than $25,000.00.
  • NAICS Code: 236220 (Commercial and Institutional Building Construction)
  • Small Business Size Standard: $45 Million
  • Wage Determination: Department of Labor Wage Determination Number 2015-4313, Revision 32 (dated April 29, 2026), applies to services performed in specific Virginia counties, including Richmond. This determination outlines minimum wage, fringe benefits, paid sick leave (EO 13706), and minimum wage rates (EO 13658).
  • Place of Performance: Defense Supply Center Richmond (DSCR), Richmond, VA.

Set-Aside & Eligibility

This is a Total Small Business Set-Aside (FAR 19.5). Contractors must be registered in the System for Award Management (SAM) at the time of quote submission. Eligibility requirements include owning, possessing, or controlling a bona fide place of business within 125 miles of DSCR and having a minimum of 5 years of experience in similar repairs. Partial proposals will not be accepted.

Submission & Evaluation

  • Proposal Submission: Via email to Contract Specialist Corinne Kuge (Corinne.Kuge@dla.mil).
  • Offer Due Date: June 12, 2026, at 11:59 PM EST (local time).
  • Evaluation Criteria: Lowest Priced Technically Acceptable (LPTA). Proposals will be evaluated as technically acceptable or unacceptable; failure to provide all required documentation will result in technical unacceptability.
  • Site Visit: A mandatory site visit is scheduled for May 26, 2026, at 10:00 AM outside Building 3. Interested parties must be vetted through security at least 5 business days prior.
  • Questions Deadline: Close of Business (COB) May 28, 2026. Questions and answers will be posted as an attachment on SAM.gov.
  • Required Submittals (prior to pre-construction meeting): Site-Specific Safety Plan, OSHA 300A Logs, Activity Hazard Analyses, and Quality Control Plan. A Quality Control System Manager must be onsite during work.

Points of Contact

People

Points of Contact

Corinne KugePRIMARY
Robert Moragues, Contracting OfficerSECONDARY

Files

Files

Download
Download
Download

Versions

Version 1Viewing
Combined Synopsis/Solicitation
Posted: May 11, 2026
DSCR B3 Roof Vent Repair | GovScope