H159--VANIHCS 3 Year Electrical Testing Marion and Fort Wayne

SOL #: 36C25026Q0067Pre-Solicitation

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
250-NETWORK CONTRACT OFFICE 10 (36C250)
DAYTON, OH, 45428, United States

Place of Performance

Marion, IN

NAICS

Electronic and Precision Equipment Repair and Maintenance (811210)

PSC

Quality Control Services: Electrical And Electronic Equipment Components (H159)

Set Aside

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) (SDVOSBC)

Timeline

1
Posted
Oct 20, 2025
2
Last Updated
Dec 17, 2025
3
Response Deadline
Nov 14, 2025, 3:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Clean, test, adjust, calibrate, inspect and retorque all the below mentioned electrical distribution apparatus. This shall include, but not be limited to, power transformers, switchgear, motor control centers, distribution centers, panel boards, air circuit breaker, vacuum circuit breakers, and loop switches listed in Attachment I SOW Attachments. Over-current testing apparatus shall be limited to over-current relays for each 15 KV and 5 KV circuit breaker. Megger voltage shall not exceed IEEE standards. No high pot voltage to be applied to feeder wires. All equipment will be isolated from panel and feeders during testing for proper data reading. No variance.

Contractor is responsible to reinstall equipment to original condition, verifying voltage, phasing and rotation. Any damage to equipment due to contractor neglect is the contractor s financial responsibility.

Repairs outside this SOW will be at an additional charge to the VA and require prior approval from the COR and Contracting Officer before repairs are started.

People

Points of Contact

Tiffany RauschContract SpecialistPRIMARY

Files

Files

No files attached to this opportunity

Versions

Version 8
Award Notice
Posted: Dec 17, 2025
View
Version 7
Solicitation
Posted: Nov 19, 2025
View
Version 6
Solicitation
Posted: Nov 17, 2025
View
Version 5
Solicitation
Posted: Nov 17, 2025
View
Version 4
Solicitation
Posted: Nov 13, 2025
View
Version 3
Solicitation
Posted: Nov 7, 2025
View
Version 2
Solicitation
Posted: Oct 23, 2025
View
Version 1Viewing
Pre-Solicitation
Posted: Oct 20, 2025