H312-- Refilling Fire Suppression System | Altoona

SOL #: 36C24426Q0654Combined Synopsis/Solicitation

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
244-NETWORK CONTRACT OFFICE 4 (36C244)
PITTSBURGH, PA, 15215, United States

Place of Performance

Altoona

NAICS

Plumbing (238220)

PSC

Inspection And Laboratory Services (Except Medical/Dental): Fire Control Equipment (H312)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Jun 5, 2026
2
Submission Deadline
Jun 18, 2026, 2:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VA) is soliciting quotes for refilling fire suppression systems at the James E. Van Zandt VA Medical Center in Altoona, PA. This is a Total Small Business Set-Aside opportunity. The solicitation number is 36C24426Q0654, and quotes are due by June 18, 2026, at 10:00 AM Eastern Standard Time.

Scope of Work

This requirement involves the refilling of the Chemetron FM-200 fire suppression system in Building 15 and the Pemhall FM-200 system in Building 11. Key services include:

  • Pre-Service Inspection and Assessment: Evaluating FM-200 systems, inspecting components for leaks/damage, verifying pressure, and ensuring compliance with NFPA 2001 (2022 edition) and manufacturer guidelines.
  • FM-200 Refilling: Safe discharge of existing agent, transport of cylinders to an approved facility, refilling to specifications, and hydrostatic testing if needed.
  • System Reinstallation and Testing: Reinstalling filled cylinders, inspecting/testing piping, actuators, and nozzles, performing pressure/leak tests, calibrating control panels, and conducting functional testing per NFPA 2001 (2022 edition).
  • Reports: Providing a detailed service report, certificate of compliance, and updating maintenance logs.
  • Safety and Compliance: Adherence to NFPA standards (2001, 70, 72, 75), ANSI 2166, VA Fire Protection Design Manual, manufacturer guidelines, and OSHA standards.

Contract & Timeline

  • Contract Type: Firm-Fixed Price
  • Period of Performance: June 25, 2026, to August 25, 2026
  • Set-Aside: Total Small Business Set-Aside (FAR 19.5)
  • NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors (Size Standard: $19 Million)
  • Solicitation Number: 36C24426Q0654 (Request for Quote - RFQ)
  • Quote Submission Deadline: June 18, 2026, 10:00 AM EST
  • Questions Submission Deadline: June 15, 2026, 10:00 AM EST
  • Published Date: June 5, 2026

Evaluation

Quotes will be evaluated based on Price and Compliance with submission instructions. The award will be made to the responsible Offeror whose quote is most advantageous to the Government.

Additional Notes

  • Quoters MUST be registered in the System for Award Management (SAM) database (www.sam.gov) to receive an award.
  • All questions must be sent via email to Loretta Payne at loretta.payne@va.gov.
  • Quotes must be submitted via email ONLY to Loretta Payne.

People

Points of Contact

Loretta PayneContract SpecialistPRIMARY

Files

Files

Download
Download

Versions

Version 1Viewing
Combined Synopsis/Solicitation
Posted: Jun 5, 2026
H312-- Refilling Fire Suppression System | Altoona | GovScope