HAWAII COMPUTER ROOM AIR HANDLING REPLACEMENT
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Defense Information Systems Agency (DISA) is soliciting proposals for the HAWAII COMPUTER ROOM AIR HANDLING REPLACEMENT project. This effort involves replacing two existing Computer Room Air Handling (CRAH) units and adding aisle containment in Computer Room 191 at the Data Center Hawaii, Pearl Harbor, HI. This is a Total Small Business Set-Aside. Proposals are due March 17, 2026, at 11:00 AM.
Scope of Work
The project requires the replacement of two end-of-life CRAH units and the installation of aisle containment. Key deliverables include:
- CRAH Unit Replacement: Installation of two self-contained, factory-assembled CRAH units with specific technical requirements (e.g., minimum 140 kW cooling capacity, SCOP-127, detailed cabinet, fan, coil, pump, reheat, filter, control valve, insulation, and control panel specifications).
- Aisle Containment: Procurement and installation of end-of-aisle doors, mounting posts, rack gap panels, and brushed rack blanking panels.
- Project Management: Includes detailed project schedules, shop drawings, and product data submittals.
- Electrical Work: Conductor and conduit requirements for the new CRAH units.
- Project Close-Out: Provision of warranties, final as-built drawings, training, and Operations & Maintenance (O&M) binders.
Mandatory Pre-Proposal Site Visit
A mandatory pre-proposal site visit will be held on Wednesday, February 25, 2026, at 1000 HST at the DISA PAC - Data Center Hawaii, 477 Essex St. (Building 77), Ford Island, JBPHH, HI 96818. Companies are limited to two representatives, and a Visit Authorization Letter (VAL) is required. Base access must be coordinated. Remarks made during the site visit do not supersede written solicitation terms. Written questions arising from the visit are due by Monday, March 2, 2026, at 1600 CST.
Contract Details
- Contract Type: Firm-Fixed-Price
- Period of Performance: 12 months upon award
- Place of Performance: Data Center Hawaii, Pearl Harbor, HI
- Set-Aside: Total Small Business Set-Aside (FAR 19.5)
- NAICS Code: 333415 (Air Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing) with a size standard of 1,250 employees.
Submission & Evaluation
Proposals must include a technical proposal and a price proposal, submitted electronically in separate files. Award will be made to the responsible offeror whose proposal represents the overall best value using a Lowest Price Technically Acceptable (LPTA) process. Evaluation factors include Technical/Management (rated Acceptable/Unacceptable) and Price. Offerors must hold prices firm for 60 calendar days.
Key Documents
Bidders should review attached documents including:
- PWS Appendix A - Concept Plans: Architectural, mechanical, electrical, and telecommunications plans.
- PWS Appendix B - DISA Labeling Std: Standards for identification and labeling of systems and equipment.
- PWS Appendix C - Electrical Safety Program: Mandatory safety standards for electrical work.
- PWS Appendix D - CRAH Units: Detailed technical specifications for the CRAH units.
- QASP - HAW Rm 191 CRAH: Outlines performance objectives, monitoring methods (100% inspection), and acceptable quality levels (100% AQL for IT rack cooling).
- Wage Determination: Service Contract Act wage rates for Hawaii.
- PWS Appendix F - DISA NDA: Non-Disclosure Agreement for contractor personnel.