HVAC Repairs for Server Room

SOL #: W912HN16S0001Sources Sought

Overview

Buyer

DEPT OF DEFENSE
Dept Of The Army
W074 ENDIST SAVANNAH
SAVANNAH, GA, 31401-3604, United States

Place of Performance

GA

NAICS

Plumbing (238220)

PSC

Air Conditioning Equipment (4120)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Mar 2, 2026
2
Response Deadline
Mar 6, 2026, 4:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of the Army, specifically W074 ENDIST SAVANNAH, is conducting a Sources Sought for market research to identify qualified businesses for HVAC Repairs for Server Room in Savannah, GA. This notice aims to determine the availability and capability of both small and large businesses. Responses are due March 6, 2026.

Purpose & Overview

This is a Sources Sought notice for market research purposes only, intended to gauge the availability and capability of qualified small businesses (including Small Disadvantaged, 8(a), Woman-Owned, HUBZone, and Service-Disabled Veteran-Owned) and large businesses. It is not a solicitation for proposals, and no contract will be awarded from this notice. No reimbursement will be made for costs associated with providing information.

Scope of Work

The contractor will be responsible for the removal and disposal of existing HVAC units and the installation of new systems in two phases:

  • Phase 1: Ground-Level System: Remove and dispose of one existing Liebert system. Supply and install one 5-ton Daikin Straight Cool Condenser (or equivalent) with a matching Air Handler and thermostat. Modify electrical, refrigerant lines, ductwork, and drainage systems. Connect to existing control wiring.
  • Phase 2: Ceiling-Mounted System: Remove and dispose of one existing ceiling-mounted Liebert system. Supply and install one 5-ton Liebert Condenser (or equivalent) with a matching Air Handler and thermostat controller. Modify electrical, refrigerant lines, ductwork, and drainage systems. Connect to existing control wiring.

General Requirements

  • Working Hours: All work must be performed during normal business hours.
  • Warranty: A comprehensive warranty for parts and labor is required.
  • Period of Performance: Project completion is required within two (2) weeks or less from contract award.

Submission Requirements

Interested parties should submit a capability statement addressing:

  • Company Information (name, address, Point of Contact, contact details, website).
  • Business Size (under NAICS code 238220).
  • Capability Narrative (description of ability to perform work, similar projects within the last three years).
  • Past Performance (at least two examples of similar projects, including title, description, period of performance, and customer POC).
  • Lead Time (potential lead times for equipment/materials impacting the two-week completion).

Contract & Timeline

  • Type: Sources Sought / Market Research
  • Set-Aside: Total Small Business Set-Aside (FAR 19.5)
  • Response Due: March 6, 2026, 4:00 PM EST
  • Published: March 2, 2026
  • Product Service Code: 4120 (Air Conditioning Equipment)

Contact Information

Additional Notes

This notice is for informational and planning purposes only and does not constitute a solicitation. Information received will be handled as proprietary if marked.