INSTALL BACK UP GENERATOR AND ATS FOR NMCI ROOM, BLDG 127, DAM NECK ANNEX

SOL #: N4008525R0072Solicitation

Overview

Buyer

Dept Of Defense
Dept Of The Navy
NAVFACSYSCOM MID-ATLANTIC
NORFOLK, VA, 23511-0395, United States

Place of Performance

Virginia Beach, VA

NAICS

Commercial and Institutional Building Construction (236220)

PSC

Repair Or Alteration Of Miscellaneous Buildings (Z2JZ)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Mar 17, 2026
2
Submission Deadline
Mar 19, 2026, 6:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of the Navy, NAVFACSYSCOM MID-ATLANTIC, is soliciting proposals for the installation of a backup generator and Automatic Transfer Switch (ATS) for the NMCI equipment room in Building 127, Dam Neck Annex, Virginia Beach, VA. This Design-Build project, a task order under an existing MACC, aims to provide critical backup power and cooling infrastructure. Proposals are due by March 19, 2026, at 2:00 PM EDT.

Project Scope

This project involves providing backup power to the NMCI equipment room's IT server racks and HVAC in Room S145 of Building 127, Taylor Hall. Key deliverables include:

  • Installation of a 75 kW diesel stand-by generator with a sub-base fuel tank.
  • Installation of an Automatic Transfer Switch (ATS) with bypass/isolation capabilities.
  • Installation of a 12-ton DX water-cooled Computer Room Air Conditioning (CRAC) unit.
  • Interior improvements, including the addition of double doors to Room S145.
  • Installation of a new 225A MLO panelboard. All work must comply with applicable codes and specifications, including UFGS 23 07 00 for insulation and a required load bank test. Building 127 must remain operational throughout construction, with utility outages scheduled for after hours.

Contract Details

  • Contract Type: Task Order under an existing Multiple Award Construction (MACC) contract (Design-Build).
  • Set-Aside: This is an 8(a) Set-Aside, restricted to listed 8(a) MACC contract holders only.
  • Estimated Value: $500,000 - $1,000,000.
  • Period of Performance: 420 calendar days from task order award.
  • Liquidated Damages: $189.14 per calendar day for delays.
  • Bonds: Performance and Payment Bonds are required within 10 calendar days of award. A Bid Guarantee (20% of offer price or $3,000,000, whichever is less) is also required.

Submission & Evaluation

  • Proposals Due: March 19, 2026, at 2:00 PM EDT.
  • Evaluation Criteria: Award will be made to the responsible offeror with the LOWEST PRICE ONLY.
  • Required Forms: Bidders must use the updated Attachment G (Price Schedule Form) and consider the updated Wage Determination (VA2260167).
  • Compliance: Offerors must address FAR 52.204-24 regarding covered telecommunications equipment or services.
  • Base Access: Personnel requiring access to NAS Oceana/Dam Neck Annex must follow specific base access procedures outlined in the "BASE ACCESS INSTRUCTION.pdf".

Contact Information

For inquiries, contact Jessica Grosso at jessica.m.grosso.civ@us.navy.mil or 757-433-3623.

People

Points of Contact

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 1Viewing
Solicitation
Posted: Mar 17, 2026
INSTALL BACK UP GENERATOR AND ATS FOR NMCI ROOM, BLDG 127, DAM NECK ANNEX | GovScope