J045--FY26 SERVICE - Backflow Preventers PM and Annual Testing (B+4) - Northport VAMC
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Department of Veterans Affairs (VA), specifically the Northport VA Medical Center in Northport, NY, has issued a Combined Synopsis/Solicitation (RFQ) for Preventive Maintenance (PM) and Annual Testing of Backflow Preventers. This acquisition is a Total Small Business Set-Aside. The requirement includes services for approximately 45 Reduced Pressure Zone (RPZ) backflow prevention assemblies and one process backflow prevention device. Offers are due April 16, 2026, at 3:00 pm EST.
Scope of Work
The contractor will be responsible for inspection, testing, preventive maintenance, repair, and replacement of backflow prevention assemblies. Services must comply with New York State Cross Connection Control (CCC) Program, NYSDOH, SCDHS requirements, and applicable VHA directives. Key tasks include:
- Field-verifying device details and updating inventory twice annually.
- Performing initial inspection and annual testing within specified timelines (10 days of award, then annually).
- All testing must be performed by a New York State-certified backflow prevention device tester.
- Submitting test results on NYSDOH-approved forms within 48 hours.
- Reporting failed assemblies immediately and proposing corrective actions.
- Using OEM-approved kits for rebuilds.
- Coordinating all work, including shutdowns, with the Contracting Officer's Representative (COR).
- Complying with VAMC Confined Space Entry Program for below-grade vaults.
- Providing unscheduled maintenance for emergency repairs via contract modification.
- Contractor must possess current NYS Backflow Prevention Device Tester Certification, NYS Master Plumber License, and Suffolk County Consumer Affairs Backflow Prevention Certification.
Contract & Timeline
- Contract Type: Request for Quotation (RFQ) - Combined Synopsis/Solicitation
- Period of Performance: One-year base period with four (4) one-year option periods (B+4).
- Place of Performance: Northport VA Medical Center, Northport, NY.
- Set-Aside: Total Small Business Set-Aside (FAR 19.5).
- NAICS Code: 238220 (Plumbing, Heating, and Air-Conditioning Contractors) with a $19 Million size standard.
- Questions Due: April 8, 2026, 3:00 pm EST.
- Q&A Posted: April 9, 2026, Close of Business (COB).
- Offer Submission Due: April 16, 2026, 3:00 pm EST.
Submission & Evaluation
Offers must be submitted electronically to Julie.monaganbarnard@va.gov in two parts: Part 1 for Technical Capability, Experience, and Veteran Involvement, and Part 2 for Price Quote. Evaluation will consider Technical Capability, Experience, Veteran Involvement, and Price. These factors are not weighted, and award will be made to the offeror whose quote is in the best interest of the Government. Offerors must be registered and verified in the Vendor Information Pages (VIP) database for Veteran-Owned Small Business credit.
Additional Notes
- A site visit will not be scheduled.
- The solicitation incorporates provisions and clauses by reference, accessible at www.acquisition.gov.
- Key attachments include the detailed Statement of Work (SOW), an RPZ Inventory List, a Pricing Worksheet, and a Wage Determination for Suffolk County, NY, which specifies minimum wage rates and fringe benefits under the Service Contract Act.