Multisizer 4e Coulter Counter

SOL #: 75N98026Q00434Pre-Solicitation

Overview

Buyer

Health And Human Services
National Institutes Of Health
NATIONAL INSTITUTES OF HEALTH OLAO
BETHESDA, MD, 20892, United States

Place of Performance

MD

NAICS

Analytical Laboratory Instrument Manufacturing (334516)

PSC

Laboratory Equipment And Supplies (6640)

Set Aside

No set aside specified

Timeline

1
Posted
May 22, 2026
2
Response Deadline
Jun 3, 2026, 1:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The National Institutes of Health (NIH), under the Department of Health and Human Services, is issuing a Presolicitation for a Multisizer 4e Coulter Counter. This advanced laboratory instrument is required to enhance functionality and analysis capabilities for cell size, counts, and distribution using the Coulter method across multiple clinical research study protocols. This notice serves as an early indication of a forthcoming solicitation. Responses are due by June 3, 2026.

Scope of Work

The required Multisizer 4e Coulter Counter must provide improved functionality and analysis capabilities. Key specifications and requirements include:

  • Measurement Method: Coulter method with patented digital pulse processing technology.
  • Core Functionality: Automatic aperture blockage detection and clearing, integrated code scanner for samples and components, fluid level monitoring, and selectable stirrer speed and direction.
  • Particle Sizing & Measurement:
    • Range: 0.2 – 1,600uM
    • Measurement Range: 2 – 80% of aperture size
    • Linearity: Diameter ± 1%, Volume ± 3%
    • Dynamic Range (Accuracy): 1:40 (diameter), 1:64,000 (volume)
  • Data Output: Comprehensive particle count, sizing, and volume distribution data (diameter, volume, area, number, percentage, and per mL metrics), along with detailed pulse distribution data.
  • Processing Capabilities: Up to 400 size classes/channels with re-processing ability, time-stamped pulses up to 525,000 per analysis, and specific modes (Total Count, Modal Count, Volumetric Count).
  • Components & Consumables: Includes specifications for aperture tubes (10uM to 2000uM), beakers (100/200mL and others), specific solutions (Isoton II Diluent, Coulter Clenz), and calibration/standard kits.
  • Installation: Required installation of the instrument.

Contract & Timeline

  • Type: Presolicitation
  • Set-Aside: None specified
  • Response Date: June 3, 2026, 1:00 PM EDT
  • Published Date: May 22, 2026
  • Product Service Code: 6640 - Laboratory Equipment And Supplies
  • Place of Performance: Maryland (MD 20892), United States

Contact Information

For inquiries, please contact John Burton at burtonjo@mail.nih.gov.

People

Points of Contact

John BurtonPRIMARY

Files

Files

Download

Versions

Version 1Viewing
Pre-Solicitation
Posted: May 22, 2026
Multisizer 4e Coulter Counter | GovScope