PKA - Wastewater Repair - B650
SOL #: FA442726R0004Pre-Solicitation
Overview
Buyer
TRAVIS AFB, CA, 94535-2632, United States
Place of Performance
CAMPO SECO X, CA
NAICS
Water and Sewer Line and Related Structures Construction (237110)
PSC
Maintenance, Repair And Rebuilding Of Equipment: Plumbing, Heating, And Waste Disposal Equipment (J045)
Set Aside
Total Small Business Set-Aside (FAR 19.5) (SBA)
Original Source
Timeline
1
Posted
Dec 19, 2025
2
Response Deadline
Jan 5, 2026, 8:00 PM
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
MEMORANDUM FOR ALL PROSPECTIVE OFFERORS
FROM: 60TH CONTRACTING SQUADRON
350 Hangar Ave; Bldg 549
Travis AFB, CA 94535
SUBJECT: Pre-Solicitation Notice FA442726R0004 – Trenchless Sewage Line Repair - Travis AFB, CA
- This notice is posted IAW FAR 5.203 “Publicizing and response time.” The Government intends to release a solicitation on or after 15 days from the date this notice for the requirement below. This notice does not obligate the government to award a contract, nor does it obligate the government to pay for any proposal preparation costs
- The contractor is to provide all supplies, materials, tools, equipment, and qualified labor necessary to investigate the extent of, and repair the damage found within the sewer line system under retail Building 650 on Travis AFB, CA 94535.
- The contractor will need to perform a video (i.e boroscope) inspection to field verify the existing pipe material/condition, size/length of pipe and fittings, and repair all sanitary sewer piping identified using a trenchless method (e.g. cured in place pipe lining).
- Perform post-repair video inspection (CCTV) of all repaired piping. Repaired piping will be free of debris and flow verified prior to placing in service.
- The contractor shall repair/replace any exterior or interior finishes (e.g. concrete, asphalt, drywall, paint, flooring, etc.) damaged during its work. The contractor is responsible for all disposal costs.
- The magnitude is expected to be from $250,000 to $500,000.
- The Government anticipates award of a firm-fixed price contract as a result of the Request from Proposal (RFP) solicitation. The RFP and all plans will be posted on and may be downloaded from SAM.gov. The RFP is anticipated to be a Total Small Business set-aside.
- No amount shall be charged to the Government for solicitation documents.
- Interested persons may state their interest to perform the requirement by emailing the point of contact listed below with the following:
- a statement of your company’s interested in attending a pre-proposal site visit and responding to a solicitation for this work in the future.
- explains your company’s capability to perform the work,
- provides any relevant/recent past performance.