Project: 640A0-26-103 Correct Steam Line Deficiencies MPD NCAIS: 238220 Classification Code: Z1NZ

SOL #: 36C26126R0027Sources Sought

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
261-NETWORK CONTRACT OFFICE 21 (36C261)
MATHER, CA, 95655, United States

Place of Performance

Palo Alto, CA

NAICS

Plumbing (238220)

PSC

Maintenance Of Other Utilities (Z1NZ)

Set Aside

No set aside specified

Timeline

1
Posted
Mar 4, 2026
2
Response Deadline
Mar 10, 2026, 5:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 21, is conducting market research through a Sources Sought Notice to identify qualified small business contractors for a Non-Recurring Maintenance (NRM) construction project. This project aims to correct critical steam line deficiencies at the VA Palo Alto Health Care System (VAPAHCS), Menlo Park Department, CA. Responses are due by March 10, 2026, at 1:00 PM Pacific Time.

Purpose

This is a Sources Sought Notice for information and planning purposes only; it is not a Request for Proposal (RFP) or any form of solicitation. The VA seeks to identify small businesses capable of performing the specified NRM construction.

Scope of Work

The project addresses end-of-life steam distribution and condensate return systems that are critically leaking and require 100% make-up water. The scope includes three primary objectives:

  • Repairs: Replace all steam and condensate equipment, components, and hardware within ten identified steam vaults. This involves draining flooded vaults and providing temporary domestic hot water to eight buildings during steam shutdowns.
  • Inspections: Conduct comprehensive investigations and inspections of the entire steam distribution and condensate return systems using professional manhole and robotic inspection cameras during scheduled shutdowns. Contractors must provide high-resolution video files and detailed deficiency reports.
  • Engineering Updates: Update the campus steam and condensate site plan, which must be stamped by a licensed Mechanical Professional Engineer (PE) in California. Detailed specifications also cover stringent safety requirements (e.g., Accident Prevention Plan, Activity Hazard Analyses, Site Safety and Health Officer), a Contractor Quality Control (CQC) system, material testing, environmental controls, and specific boiler plant and piping system standards.

Contract Details & Timeline

  • Opportunity Type: Sources Sought (Market Research)
  • Estimated Magnitude: Between $2,000,000 and $5,000,000.
  • Period of Performance: 120 calendar days from the Notice to Proceed (NTP), with all work to conclude by September 30, 2026.
  • Performance Constraints: System shutdowns are strictly limited to July, August, or September to minimize impact on patients and staff.
  • NAICS Code: 238220 (Plumbing, Heating, and Air-Conditioning Contractors) with a $19 Million size standard.
  • Product Service Code: Z1NZ (Maintenance of Other Utilities).
  • Place of Performance: VA Palo Alto Health Care System, Menlo Park Department, Palo Alto, CA.

Submission Requirements

Interested and capable firms are requested to submit a brief Capability Statement (maximum 5 pages) via email. The statement must include:

  • Company Profile: Name, address, Unique Entity Identifier (UEI), and Point of Contact information.
  • Socioeconomic Status: Indicate business size under NAICS 238220. Service-Disabled Veteran-Owned Small Businesses (SDVOSB) or Veteran-Owned Small Businesses (VOSB) must be certified in the SBA VetCert database.
  • Bonding Capacity: A letter from a surety company confirming the firm's ability to bond for a single project of at least $2.5 Million.
  • Relevant Experience: Descriptions of 2-3 recent projects (within the last 5 years) of similar size, scope, and complexity, specifically involving industrial/hospital steam distribution systems, high-pressure steam vault repairs, and robotic pipeline inspections.

Deadline & Contacts

People

Points of Contact

Edwin RiveraPRIMARY
Jose HernandezSECONDARY

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 1Viewing
Sources Sought
Posted: Mar 4, 2026
Project: 640A0-26-103 Correct Steam Line Deficiencies MPD NCAIS: 238220 Classification Code: Z1NZ | GovScope