The contractor shall provide all labor, supervision, management, materials, equipment (such as cabling, duct work and power generation) for the rental, delivery, and maintenance of HVAC units. The HVAC units shall be self-supported units with hoses hooked to erected 16’x 32’ GP medium tents with diesel generators. The contractor shall provide a separate self-supported HVAC system to each of the four (4) GP Medium tents.
Each HVAC unit shall heat/cool the 16’x 32’ GP Medium tents with insulated rating of R1, dirt base flooring, and interior temperature range between 72 and 78 degrees Fahrenheit at all times. The 16 personnel staying in the GP Medium tents will provide constant travel in and out of the tent. The HVAC units shall have the capability to feed two (2) 20” tent penetration points. The penetration points are on one end of the tent, approximately 2-foot above the ground
Industry Questions and Answers have been uploaded as an attachement.