Renovate HVAC Building 2007

SOL #: FA3016-17-R-0091Pre-Solicitation

Overview

Buyer

DEPT OF DEFENSE
Dept Of The Air Force
FA3016 502 CONS CL
JBSA LACKLAND, TX, 78236-5286, United States

Place of Performance

SAN ANTONIO, TX

NAICS

Plumbing (238220)

PSC

Maint, Repair, Alter Real Property (Z)

Set Aside

Women-Owned Small Business (WOSB) Program Set-Aside (FAR 19.15) (WOSB)

Timeline

1
Posted
Aug 8, 2017
2
Last Updated
Sep 8, 2017
3
Response Deadline
Sep 13, 2017, 9:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

 

Question:

Revised Section 01 11 00 paragraph 1.4.b states, "The Noise Criterion (NC) for the project area within the building is 35db. All new VAV and air side units shall be attenuated such that all new and interdicted ductwork and the balanced air flow shall meet the NC."  Does the Government require maximum 35dB or NC35 for Room 119C?  In our opinion, limiting the Contractor to straight 35dB across all frequencies is not feasible for this project.  The following highlights the difference between "dB" levels and "NC" ratings:

Noise Criterion (NC) were established in the U.S. for rating indoor noise like noise from air-conditioning equipment and similar. In Europe it is common to use the Noise Rating Curve - NR <http://www.engineeringtoolbox.com/nr-noise-rating-d_60.html> .  The method consists of a set of criteria curves ranging 63 to 8000 Hz and a tangency rating procedure. The criteria curves defines the limits of octave band spectra that must not be exceeded to meet the occupants acceptance in the actual spaces.  The NC rating can be determined by plotting the octave band levels for a given noise spectrum - the NC curves. The noise spectrum is specified as having a NC rating same as the lowest NC curve which is not exceeded by the spectrum.

 

Answer:

Noise level is acceptable 35db to 40db or acceptable levels as per office building industry standards.

People

Points of Contact

edward chilsonMr.PRIMARY

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 5Viewing
Pre-Solicitation
Posted: Sep 8, 2017
Version 4
Pre-Solicitation
Posted: Sep 7, 2017
View
Version 3
Pre-Solicitation
Posted: Sep 6, 2017
View
Version 2
Pre-Solicitation
Posted: Aug 30, 2017
View
Version 1
Pre-Solicitation
Posted: Aug 8, 2017
View
Renovate HVAC Building 2007 | GovScope