H--SEKI BACKFLOW/FIRE PROTECTION ITM (FY26)

SOL #: 140P8526Q0052Solicitation

Overview

Buyer

Interior
National Park Service
PWR SF/SEA MABO(85000)
SAN FRANCISCO, CA, 94104, United States

Place of Performance

Place of performance not available

NAICS

Building Inspection Services (541350)

PSC

Inspection And Laboratory Services (Except Medical/Dental): Alarm, Signal, And Security Detection Systems (H363)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Apr 15, 2026
2
Last Updated
May 1, 2026
3
Submission Deadline
May 12, 2026, 7:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The National Park Service, Sequoia and Kings Canyon National Parks, requires fire equipment testing, maintenance, and inspection services, specifically for Backflow and Fire Protection ITM (Inspection, Testing, and Maintenance). This is a Request for Quotation (RFQ) for a firm fixed-price commercial services contract, issued as a Total Small Business Set-Aside. Quotes are due May 12, 2026, by 12:00 P.M. Pacific Time (PT).

Scope of Work

The contractor will perform annual inspection, testing, and maintenance of water and fire protection systems at various locations within Sequoia and Kings Canyon National Parks. This includes:

  • Backflow Prevention Assemblies: Annual inspection and testing of 38 assemblies, ensuring compliance with federal, state, and local regulations. Documentation, certification, and identification of deficiencies are required. Approved repairs, replacements, or installations may be performed.
  • Structural Fire Protection Systems: Annual inspection, testing, and maintenance of fire alarm and automatic fire sprinkler systems, adhering to applicable codes and standards (e.g., NFPA 72, NFPA 25). Documentation, deficiency reporting, and cost estimates for corrective actions are necessary. A Site-Specific Safety and Health Plan is required prior to work commencement. Work must be completed within 60 days of the Notice to Proceed, with a Period of Performance from June 1, 2026, to July 30, 2026.

Contract Details

  • Solicitation Number: 140P8526Q0052
  • Contract Type: Firm Fixed-Price Commercial Services Contract (RFQ)
  • Set-Aside: Total Small Business Set-Aside (FAR 19.502-2)
  • NAICS Code: 541350 (Building Inspection Services)
  • Size Standard: $11.5 Million
  • Place of Performance: Sequoia and Kings Canyon National Parks, CA
  • Period of Performance: June 1, 2026, to July 30, 2026

Submission & Evaluation

  • Quotes Due: May 12, 2026, 12:00 P.M. PT.
  • Submission Method: Emailed quotes only to brian_roppolo@nps.gov, in Adobe PDF format.
  • Questions Due: May 5, 2026, 12:00 P.M. PT, via email to brian_roppolo@nps.gov, referencing the solicitation number.
  • Evaluation Factors: Price, Technical Approach (compliance, realism, efficiency, scope understanding, low risk), and Relevant Experience (comparable projects within the last six years).
  • Site Visit: A site visit is scheduled for April 29, 2026. Attendance is not required but is urged.

Key Attachments

The solicitation includes several attachments, such as the Statement of Work (SOW), Backflow Preventer Assembly List, NPS Standard ITM Forms, NPS Standard Backflow form, and Wage Determination 2015-5657 for Tulare County, CA. Amendment 0001 added an Asset List Inventory and Combined NPS Reports.

People

Points of Contact

Roppolo, BrianPRIMARY

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 2Viewing
Solicitation
Posted: May 1, 2026
Version 1
Solicitation
Posted: Apr 15, 2026
View
H--SEKI BACKFLOW/FIRE PROTECTION ITM (FY26) | GovScope