Station Washington sprinkler system repairs

SOL #: 30252PR260000013Solicitation

Overview

Buyer

Homeland Security
Us Coast Guard
BASE NATIONAL CAPITAL REGION(000G8)
WASHINGTON, DC, 20593, United States

Place of Performance

Washington, DC

NAICS

Fire Protection (92216)

PSC

Fire Control Systems, Complete (1230)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Apr 8, 2026
2
Submission Deadline
Apr 24, 2026, 4:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The U.S. Coast Guard, under the Department of Homeland Security, is soliciting quotes for sprinkler system repairs at Station Washington, Buildings 91 and 92, located on Joint Base Anacostia-Bolling, Washington D.C. This opportunity is a Total Small Business Set-Aside for a Firm-Fixed Price (FFP) Purchase Order. The work involves replacing defective dry sprinkler system valves. Quotes are due by April 24, 2026, at 12:00 PM EDT.

Scope of Work

The contractor will provide all labor, materials, and equipment to:

  • Remove and replace defective dry sprinkler system valves in Buildings 91 and 92.
  • Replace the trim kits for both dry sprinkler systems.
  • Test and reset both dry sprinkler systems, including draining residual water.
  • Clear all trouble alarms associated with the sprinkler system from the fire detection system. Work must commence no later than seven (7) days after notice to proceed and be completed within twenty-one (21) working days after contract award.

Contract Details

  • Contract Type: Firm-Fixed Price (FFP) Purchase Order
  • Set-Aside: Total Small Business Set-Aside (FAR 19.5)
  • Product Service Code (PSC): 1230 (Fire Control Systems, Complete)
  • NAICS Code: 332919 (Other Fabricated Metal Product Manufacturing)
  • Place of Performance: U.S. Coast Guard Station Washington, Buildings 91 and 92, Joint Base Anacostia-Bolling, 3870 Giovannoli St SW, Washington DC, 20032.

Key Dates & Submission

  • Site Visits: Strongly encouraged between April 9-17, 2026 (0800-1400). Contact MKC James Tooker at 202-591-5944 or james.g.tooker@uscg.mil to arrange.
  • Questions Deadline: Tuesday, April 21, 2026, 12:00 PM EDT. Submit via email to SK2 Isiah Mack (Isiah.R.Mack@uscg.mil) and CWO-2 Daniel Negron (Daniel.J.Negron@uscg.mil).
  • Quote Submission Deadline: Friday, April 24, 2026, 12:00 PM EDT.
  • Submission Method: Email quotes.
  • Quote Format: Two volumes: Technical Capability (max 5 pages) and Price (using the provided Excel spreadsheet).

Evaluation Criteria

Award will be based on the Lowest Price, Technically Acceptable (LPTA) method. Technical capability will be evaluated first, and an "Acceptable" rating is required for price consideration.

Points of Contact

People

Points of Contact

Files

Files

Download
Download
Download

Versions

Version 1Viewing
Solicitation
Posted: Apr 8, 2026
Station Washington sprinkler system repairs | GovScope