WBAMC Surgical Aspirator - Liposuction

SOL #: PANHCA-26-P-0000-026646Sources Sought

Overview

Buyer

DEPT OF DEFENSE
Dept Of The Army
W40M MRC0 WEST
JBSA FT SAM HOUSTON, TX, 78234-4504, United States

Place of Performance

Fort Bliss, TX

NAICS

Electromedical and Electrotherapeutic Apparatus Manufacturing (334510)

PSC

Medical And Surgical Instruments, Equipment, And Supplies (6515)

Set Aside

No set aside specified

Timeline

1
Posted
May 27, 2026
2
Response Deadline
Jun 2, 2026, 4:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of the Army is conducting market research for the William Beaumont Army Medical Center (WBAMC), Fort Bliss, TX, to identify potential sources for a Surgical Aspirator - Liposuction System. This Sources Sought notice aims to determine an acquisition strategy for a system required by the Department of Plastic Surgery for medical readiness. Responses are due by June 2, 2026.

Scope of Work

WBAMC requires one FDA-approved, most current, ergonomic, and integrated surgical aspirator liposuction system. Key features include the ability to infiltrate tumescent fluid (5-10 micron bubbles), produce acoustic energy via an ultrasonic probe for fat emulsification, and utilize a small-diameter cannula. The system must have an ultrasonic operating frequency of 36 kHz, precise suction pressure control, and an ultrasonic amplifier with continuous and pulsed wave energy. It should also include a replaceable suction filter, digital fluid tracking up to 4500 mL, and attachments for four 1,250 mL collection cannisters. A peristaltic infiltration pump and wireless footswitch are also required.

The requirement includes onsite installation by an authorized OEM installer, who will be responsible for all tools, materials, removal, and disposal, adhering to specific post access and hospital check-in procedures. Onsite training for clinical staff and clinical engineers at WBAMC is also mandatory. Delivery is required no later than 60 calendar days from contract award, with no partial deliveries, and must include proper package marking and prior notification to the COR.

Contract & Timeline

  • Type: Sources Sought / Market Research
  • Set-Aside: None specified (market research stage)
  • Response Due: June 2, 2026, by 4:00 PM Z
  • Published: May 27, 2026

Evaluation

Responses will be used for market research purposes to determine an acquisition strategy. This notice is for planning only and does not guarantee a future solicitation.

Additional Notes

Sellers must be an authorized dealer, distributor, or reseller, and provide an OEM warranty. The system is crucial for treating Active-Duty soldiers with symptomatic macromastia affecting their ability to perform military duties.

People

Points of Contact

Files

Files

Download

Versions

Version 1Viewing
Sources Sought
Posted: May 27, 2026
WBAMC Surgical Aspirator - Liposuction | GovScope