XTLF 15-1018 Repair AA&E Storage at F527

SOL #: FA3029-25-R-0007Solicitation

Overview

Buyer

DEPT OF DEFENSE
Dept Of The Air Force
FA3029 71 FTW CVC
ENID, OK, 73705-5037, United States

Place of Performance

Enid, OK

NAICS

Commercial and Institutional Building Construction (236220)

PSC

Repair Or Alteration Of Miscellaneous Buildings (Z2JZ)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Jul 2, 2025
2
Last Updated
Jul 29, 2025
3
Submission Deadline
Aug 15, 2025, 3:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Notice to Offeror(s) and Supplier(s): Funds are not presently available for this effort. No award will be made under this solicitation until funds are available. Once funds are available, bid guarantee will be required before award. The Government reserves the right to cancel this solicitation, either before or after the closing date for receipt of proposals. In the event the Government cancels this solicitation, the Government has no obligation to reimburse an offeror for any cost.

The purpose of this solicitation is to notify prospective contractors on the performance of construction services for project XTLF 15-1018 Repair AA and E Storage at F527. This service will renovate building 527 to comply with UFC 04-026-01 and MIL-HNDBK 1013/1A. The building requires minor renovations to eliminate deviation request VANCE AFB 97-01. These renovations include the reinforcement of the existing AA and E storage room by adding steel and plywood layers to surrounding interior walls and ceiling. In addition, existing fixtures will be removed and reinstalled on the new wall and ceiling faces, the entry door will be replaced with a compliant door, and window fasteners will be replaced with compliant tamper-resistant fasteners. Circuits on the interior electrical panel dedicated to other areas of the facility will be relocated to a new panel outside the room, providing better access to emergency personnel. AA and E Risk Categories II through IV must be stored in a structure with a minimum forced entry resistance of 10 minutes against threat severity level III. 

People

Points of Contact

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 2
Solicitation
Posted: Jul 29, 2025
View
Version 1Viewing
Solicitation
Posted: Jul 2, 2025
XTLF 15-1018 Repair AA and E Storage at F527 | GovScope