Z2FE--Renovate B119 Catholic Chapel [552-22-201]
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Department of Veterans Affairs (VA), specifically the NETWORK CONTRACT OFFICE 10 (36C250), has issued a Solicitation for the Renovation of Catholic Chapel B119 at the VA facility in Dayton, Ohio. This opportunity is a Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside. This amendment provides updated drawings critical for understanding the project scope, which includes structural, architectural, and utility system renovations. Proposals are due by February 18, 2026, at 5:00 PM ET.
Project Scope
This project involves the comprehensive renovation of Catholic Chapel B119 located at 4100 W. Third St., Dayton, Ohio. Key areas of work include structural repairs, floor and masonry tuckpointing, and potential utility work. The scope also covers grading and erosion control measures. Bidders are strongly advised to conduct a site visit and field verify all conditions and dimensions to ensure accurate proposals. Compliance with applicable codes and standards, including IBC, ASCE 7, VA Handbooks, and ODOT CMS, is mandatory.
Key Documents & Updates
This solicitation includes updated architectural and engineering drawings (Document: 552-22-201_Renovate Catholic Chapel B119_Drawings 07Nov25.pdf) which detail existing conditions and proposed renovations. These drawings encompass:
- Architectural Plans: Cover sheet, code data, existing and new work plans, demolition, interior elevations, reflected ceiling plans, roof plans, and detailed schedules (doors, finishes, accessories).
- Structural, Civil, Mechanical, Electrical, Plumbing Plans: Detailed layouts for drainage, distribution, ductwork, piping, power, lighting, and equipment.
- Technology & Control Drawings: Plans for telecommunications, AV, fire alarm, network systems, and HVAC control sequences.
- Special Requirements: Detailed schedules for special inspections (soils, concrete, structural steel, wood construction). A Geotechnical Engineer's Report by Terracon (dated 11/12/2024) is referenced and available upon request.
Contract Details
- Contract Opportunity Type: Solicitation
- Product Service Code: Z2FE - Repair Or Alteration Of Religious Facilities
- Set-Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
- Place of Performance: Dayton, OH 45428, United States
- Response Due Date: February 18, 2026, 5:00 PM ET
- Published Date: January 29, 2026
Contact Information
For inquiries, contact Jenessa M Regan at Jenessa.Regan@va.gov.