Collin Haupt (Makah) WPS and OSS
Overview
Buyer
Place of Performance
NAICS
PSC
Set Aside
Original Source
Timeline
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Indian Health Service (IHS), specifically the DIV OF ENGINEERING SVCS - SEATTLE, has issued a Request for Quote (RFQ) for the Collin Haupt (Makah) WPS and OSS project. This opportunity, a Total Small Business Set-Aside, involves the installation of an individual septic system and a water pressure system for a private residence in Neah Bay, WA. The estimated magnitude of construction is between $25,000.00 and $100,000.00. Proposals are due by March 18, 2026, at 2:00 pm CST.
Scope of Work
The project requires the contractor to install a complete individual septic system and a water pressure system. Key components include:
- Septic System: Installation of a 4-inch PVC gravity sewage transport pipe, underground cleanout, a 1,000-gallon two-compartment concrete septic tank, a 1,000-gallon pump chamber with an effluent pump (Orenco model PF100511 or equivalent), and approximately 750 square feet of subsurface Netafilm Bioline dripline.
- Water Pressure System: Removal of existing temporary well cap, installation of a 3/4 HP submersible pump (Goulds 10G07 or equivalent) at 162 ft depth, 162 linear feet of 1" Schedule 120 PVC drop pipe and submersible cable, a pitless adapter, metal well cap, 155 feet of 1" SCH 40 PVC water service line to the house, a variable frequency drive (Aquavar SOLO2 or equivalent) in a standalone structure, a 2-gallon pressure tank, and approximately 200 feet of electrical conduit to the home subpanel.
- Compliance: All work must adhere to County-approved designs, IHS Technical Provisions, and local, state, and Tribal regulations, including Washington Administrative Codes (WAC) for On-site Sewage Systems, Tanks, Building Codes, Electrical Safety, and Well Construction.
Contract Details
- Contract Type: Firm Fixed Price
- Estimated Magnitude: $25,000.00 to $100,000.00
- Set-Aside: Total Small Business Set-Aside (FAR 19.5)
- NAICS Code: 237110 (Water and Sewer Line and Related Structures Construction) with a size standard of $45.0 million.
- Period of Performance: 45 calendar days from the issuance of the Notice to Proceed (NTP).
- Place of Performance: Neah Bay, Clallam County, WA.
Submission & Evaluation
- Proposal Submission Deadline: March 18, 2026, at 2:00 pm CST.
- Submission Method: Electronically in PDF format via email to Robert.Miller2@ihs.gov.
- Questions Due: No later than 7 days prior to the proposal due date (March 11, 2026).
- Evaluation Criteria: Award will be based on price and the quoter's compliance with terms and conditions, with price being the discriminating factor.
- Required Submissions: Offerors must submit a copy of their current septic installer license and a narrative (MS Word or PDF) stating their ability to install a water pressure system.
- Bonds: Performance and Payment Bonds ARE required. A Bid Guarantee is NOT required.
- Wage Determination: Compliance with U.S. Department of Labor Wage Determination WA20260081 (effective January 2, 2026) for Clallam County, WA, is mandatory.
Additional Notes
Offerors must be registered in the System for Award Management (SAM) database. A formal site visit is not applicable; contractors should contact the homeowner directly for site investigation. The contractor is responsible for obtaining all necessary permits. A pre-construction meeting is required unless waived by the COR. TERO fees do not apply.