J041-- Boiler Plant Control Systems Preventative Maintenance Services B+4

SOL #: 36C24726Q0127Award Notice

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
247-NETWORK CONTRACT OFFICE 7 (36C247)
AUGUSTA, GA, 30904, United States

Place of Performance

Columbia, SC

NAICS

Facilities Support Services (561210)

PSC

Maintenance, Repair And Rebuilding Of Equipment: Refrigeration, Air Conditioning, And Air Circulating Equipment (J041)

Set Aside

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) (SDVOSBC)

Timeline

1
Posted
Nov 24, 2025
2
Last Updated
Apr 30, 2026

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VA), Network Contract Office 7, is soliciting proposals for Boiler Plant Control Systems Preventative Maintenance Services at the William Jennings Bryan Dorn VA Medical Center in Columbia, SC. This opportunity is a Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside for a Firm-Fixed Price contract. The services include annual preventative maintenance and repair for seven boilers and associated systems. Proposals are due by December 15, 2025, at 10:00 AM EST.

Scope of Work

The contractor will provide all labor, travel, equipment, supplies, and materials for annual preventative maintenance and repair services for seven boilers (four dual fuel, three single fuel) and their associated control systems. Key services include:

  • Server and software maintenance.
  • Combustion control point calibration and testing.
  • Safety switch calibration and testing, including High Steam Pressure Limit Switches (HBSPLS) and High-High Boiler Steam Pressure Limit Switches (HHBSPLS) as per specific VA procedures.
  • Boiler plant loop tuning and common plant instrumentation maintenance.
  • Lochinvar boiler checks and gas detection system maintenance.
  • One annual and one semi-annual testing per boiler.
  • Routine repairs with a response time of less than 24 hours.
  • Emergency service and after-hours response, with a 2-hour response for critical repairs (e.g., Master Control Panel) and N+1 boiler repairs.
  • Provision of written field service reports and training for VA personnel on equipment operation.
  • Personnel must have 10-Hour OSHA training and be fully trained on Fireye Controls. Compliance with the "VHA Boiler and Associated Plant Safety Device Testing Manual, Eighth Edition" (Feb 2024) is required.

Contract Details

  • Contract Type: Firm-Fixed Price.
  • Period of Performance: A base year (May 1, 2026 - April 30, 2027) with four (4) one-year option periods, extending through April 30, 2031.
  • Place of Performance: William Jennings Bryan Dorn VA Medical Center, Columbia, SC 29209.
  • NAICS Code: 561210 (Facilities Support Services) with a size standard of $47.0 Million.
  • Product Service Code: J041 (Maintenance, Repair And Rebuilding Of Equipment: Refrigeration, Air Conditioning, And Air Circulating Equipment).
  • Set-Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB). Offerors must be registered in SAM.gov and SBA verified (VetCert) at the time of offer submission and award.

Submission & Evaluation

  • Proposal Deadline: December 15, 2025, 10:00 AM EST.
  • Submission Method: Electronically via email to LaTerrica.Sewell@va.gov. Quotes must be in PDF, preferably one document, not exceeding ten pages.
  • Evaluation Factors: Best Value, considering Technical, Past Performance, and Price. Technical evaluation will assess understanding, plan of action, knowledge, and detail on equipment/personnel. Past Performance requires a minimum of two references for similar services within the last four years. Price will be evaluated for fairness and reasonableness.
  • Site Visit: A mandatory site visit is scheduled for December 4, 2025, from 9:00 AM - 11:00 AM EST at the Boiler Plant, Building 21. This is the only scheduled site visit.
  • Questions Deadline: December 8, 2025, 10:00 AM EST, submitted via email to LaTerrica.Sewell@va.gov. Answers to vendor questions and safety check protocols have been provided via Amendment 0001.

Additional Notes

Offerors must submit a completed VAAR 852.219-75 certification and provide a subcontracting plan if not self-performing 100% of the requirement.

People

Points of Contact

LaTerrica SewellContracting OfficerPRIMARY

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 5Viewing
Award Notice
Posted: Apr 30, 2026
Version 4
Award Notice
Posted: Jan 28, 2026
View
Version 3
Combined Synopsis/Solicitation
Posted: Jan 28, 2026
View
Version 2
Combined Synopsis/Solicitation
Posted: Dec 10, 2025
View
Version 1
Combined Synopsis/Solicitation
Posted: Nov 24, 2025
View
J041-- Boiler Plant Control Systems Preventative Maintenance Services B+4 | GovScope