J047--Replace Backflow Preventer 610A4-26-501

SOL #: 36C25026Q0313Solicitation

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
250-NETWORK CONTRACT OFFICE 10 (36C250)
DAYTON, OH, 45428, United States

Place of Performance

Fort Wayne, IN

NAICS

Plumbing (238220)

PSC

Maintenance, Repair And Rebuilding Of Equipment: Pipe, Tubing, Hose, And Fittings (J047)

Set Aside

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) (SDVOSBC)

Timeline

1
Posted
Feb 13, 2026
2
Last Updated
Mar 16, 2026
3
Submission Deadline
Mar 27, 2026, 2:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VA), specifically the VA Northern Indiana Health Care System in Fort Wayne, IN, has issued a Solicitation for the replacement and relocation of a backflow preventer and associated valves in Building 1. This is a Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside opportunity. Proposals are due by March 27, 2026, at 2:00 PM ET.

Scope of Work

The contractor will provide all labor, materials, equipment, supervision, and project management to:

  • Replace and relocate a 4-inch backflow preventer (new device provided by VA).
  • Replace two isolation valves (new valves provided by VA).
  • Run new piping from the existing water main to the new backflow preventer at ground level.
  • Replace one 6-inch gate isolation valve.
  • Test the new system with a certified backflow tester and submit proper paperwork.
  • Coordinate all shutdowns with the Contracting Officer's Representative (COR) at least two weeks in advance.
  • Adhere to all applicable federal, state, municipal laws, codes, regulations, and VHA Master Specifications.
  • Provide a site-specific safety plan, proposed performance schedule, estimate, and submittals to the COR prior to installation.

Contract Details

  • Contract Type: Firm-Fixed-Price
  • Period of Performance: 90 calendar days after Notice to Proceed (NTP)
  • Set-Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • NAICS Code: 238220 (Plumbing, Heating, and Air-Conditioning Contractors) with a size standard of $19.5 Million.

Submission & Evaluation

Offers must be submitted electronically to tiffany.rausch@va.gov by the closing date and time. Evaluation will be based on price and other factors, with technical capability and past performance being significant. Offerors must acknowledge receipt of any amendments.

Key Dates & Contacts

  • Solicitation Published: March 3, 2026
  • Pre-Award Site Visit: Friday, March 13, 2026, at 1:00 PM ET, located at 2121 Lake Ave., Fort Wayne, IN 46805, Building 4.
  • Proposal Due Date: March 27, 2026, 2:00 PM ET
  • Contact: Tiffany A Rausch, Contract Specialist, Tiffany.Rausch@va.gov

Important Attachments & Notes

Bidders must complete and return VAAR 852.219-75, "VA Notice of Limitations on Subcontracting—Certificate of Compliance," which outlines subcontracting restrictions for SDVOSBs/VOSBs. The Service Contract Act Wage Determination for Indiana counties applies, impacting labor costs. Detailed technical specifications, piping diagrams, and basement drawings are provided for understanding the scope. Prep work can occur during normal hours, but the actual outage and tie-in must be outside normal working hours.

People

Points of Contact

Tiffany A RauschContract SpecialistPRIMARY

Files

Files

Download
Download
Download
Download
Download
Download
View
Download

Versions

Version 4
Solicitation
Posted: Mar 16, 2026
View
Version 3Viewing
Solicitation
Posted: Mar 3, 2026
Version 2
Solicitation
Posted: Feb 24, 2026
View
Version 1
Sources Sought
Posted: Feb 13, 2026
View
J047--Replace Backflow Preventer 610A4-26-501 | GovScope