59--SF6 CIRCUIT BREAKER OVERHAULT KIT

SOL #: 140R1726Q0024Solicitation

Overview

Buyer

Interior
Bureau Of Reclamation
GRAND COULEE POWER OFFICE
GRAND COULEE, WA, 99133, United States

Place of Performance

Place of performance not available

NAICS

Switchgear and Switchboard Apparatus Manufacturing (335313)

PSC

Circuit Breakers (5925)

Set Aside

Economically Disadvantaged WOSB (EDWOSB) Program Set-Aside (FAR 19.15) (EDWOSB)

Timeline

1
Posted
May 5, 2026
2
Last Updated
Jun 3, 2026
3
Submission Deadline
May 28, 2026, 9:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of the Interior, Bureau of Reclamation, Grand Coulee Power Office is soliciting for SF6 Circuit Breaker Overhaul Kits for ABB HECI-3R generator circuit breakers. This requirement is for a 15-year overhaul at the Grand Coulee Dam, Washington, to ensure the efficient and safe operation of critical equipment. This is a single-source procurement for proprietary parts from Hitachi Energy. Quotes are due by May 28, 2026, at 5 PM Eastern.

Scope of Work

The requirement is for one (1) SF6 Circuit Breaker Overhaul Kit (Type HECI-3/R). Key deliverables include:

  • A manufacturer-generated list of all applicable part numbers.
  • A cut sheet or similar documentation with dimensions and drawings for technical review.
  • One copy of the Operations and Maintenance Manual Repair Kit, covering installation, operation, maintenance, repair, and troubleshooting.
  • A minimum one-year warranty on all parts. Technical specifications for the breaker, as detailed in the provided nameplate, include a rated maximum voltage of 25.3kV, continuous current of 8600A, and a rated short-circuit current of 100kA.

Contract Details

  • Contract Type: Solicitation (RFQ/IFB)
  • Estimated Delivery: 20 weeks after receipt of order.
  • Delivery Date: December 31, 2026.
  • Payment: Via Invoice Processing Platform (IPP).

Eligibility & Set-Aside

This acquisition has been determined to be a single-source procurement from Hitachi Energy. Market research confirmed that only genuine Hitachi Energy brand SF6 circuit breaker parts can be used without risking equipment damage or jeopardizing safety, as these are specialized and proprietary parts unique to the specified breaker model. This determination was made under Simplified Acquisition Procedures (SAT).

Submission & Evaluation

  • Quote Submission Deadline: May 28, 2026, 5 PM Eastern.
  • Submission Instructions: Submit pricing along with the manufacturer-generated listing of all applicable part numbers to Donald Richer at DONALD_RICHER@IOS.DOI.GOV.
  • Evaluation: Price reasonableness will be determined in accordance with FAR 12.204(a).
  • Acknowledgement: Offerors must acknowledge receipt of all amendments by signing, dating, and submitting them with their quote.

Key Updates & Amendments

  • Amendment 0001: Added the single-source determination.
  • Amendment 0002: Extended the closing date for quotes to May 28, 2026.
  • Amendment 0003: Included a picture of the SF6 circuit breaker nameplate, providing detailed technical specifications.

Contact Information

People

Points of Contact

Files

Files

Download
Download
Download
Download

Versions

Version 5
Solicitation
Posted: Jun 3, 2026
View
Version 4Viewing
Solicitation
Posted: May 14, 2026
Version 3
Solicitation
Posted: May 13, 2026
View
Version 2
Solicitation
Posted: May 5, 2026
View
Version 1
Solicitation
Posted: May 5, 2026
View