TVHS VAMC Air Handler Units Refurbishment

SOL #: 36C24926Q0177Special Notice

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
249-NETWORK CONTRACT OFFICE 9 (36C249)
MURFREESBORO, TN, 37129, United States

Place of Performance

Nashville, TN

NAICS

Plumbing (238220)

PSC

Maintenance Of Hospitals And Infirmaries (Z1DA)

Set Aside

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) (SDVOSBC)

Timeline

1
Posted
Apr 2, 2026
2
Last Updated
May 7, 2026
3
Action Date
May 18, 2026, 4:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VA), Network Contract Office 9, is soliciting quotes for the refurbishment of Air Handler Units (AHUs) at the Tennessee Valley Healthcare System (TVHS) VAMC in Nashville, TN. This is a 100% Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside. The deadline for offer submission has been extended to May 18, 2026, at 11:00 AM CDT.

Purpose & Scope of Work

This Request for Quote (RFQ) seeks services to replace components and perform repairs on specific Air Handler Units (AHU-41, AHU-40, AHU-39, AHU-24, AHU-4) at the TVHS VAMC. The goal is to extend the usable life of these critical units. The work encompasses coil replacement, drain work, valve replacement, fan motor/assembly replacement, humidifier replacement, UV lighting system installation, and Variable Frequency Drive (VFD) replacement. Temporary HVAC must be provided when AHUs are non-functional. All work must adhere to detailed specifications and industry standards.

Contract Details

  • Contract Type: Firm-Fixed-Price
  • Period of Performance: 365 calendar days from the date of award, anticipated July 15, 2026, to July 14, 2027.
  • Set-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB). Offerors must be SBA-certified and listed in the SBA database at the time of offer and award.
  • Place of Performance: Nashville, TN 37212.
  • Applicable Wage Determination: WD 2015-4647, Rev 30, Dated 12/03/2025, for the specified Tennessee counties.

Submission & Evaluation

  • Offer Submission Deadline: May 18, 2026, at 11:00 AM CDT.
  • Submission Method: Submittals are preferred via Procore or similar platforms; email is not accepted for final submissions.
  • Evaluation Criteria: Best value, considering price, Technical Approach (Technical Plan and Quality Control Plan), and Past Performance.
  • Acknowledgement: Offerors must acknowledge receipt of Amendment 0003. Changes to previously submitted offers can be made via letter or electronic communication before the new deadline.

Key Requirements & Clarifications

  • Technical Specifications: Detailed specifications for HVAC systems, motors, fans, AHUs, and air coils are provided and crucial for bidders.
  • Quality Control Plan (QCP): A contractor-provided QCP is required.
  • Test and Balance Reports: Pre-work and post-work Test and Balance reports are mandatory.
  • Infection Control & Safety: Adherence to VHA Infection Control Risk Assessment (ICRA), Pre-Construction Risk Assessment (PCRA), and Interim Life Safety Measures (ILSM) protocols is critical. Bidders should meet with Industrial Hygiene (IH) to complete PCRA/ICRA documentation.
  • Superintendent: Must be a direct employee of the Prime Contractor. Dual roles (Superintendent/SSHO/QCM) may be permissible if qualified, but a dedicated Safety and Health Officer (SSHO) may be requested if performance is unsatisfactory.
  • Siemens BAS Integration: Contractors must use a VA-approved Siemens vendor for Building Automation System (BAS) integration.
  • Temporary HVAC: Must maintain full normal service for AHUs 39, 40, and 41 during outages. Roof certification for temporary units may not be needed if placed downstairs.
  • Buy American Act: No waivers are currently planned, with exemptions for foreign spare/replacement parts if domestic parts are unavailable.
  • UV Lighting System: Must comply with VA Master Specification 23 40 00, including specific performance and 254 nm wavelength.

Contact Information

For inquiries, contact Scott Dickey at scott.dickey@va.gov or 615-225-5635.

People

Points of Contact

Scott DickeyPRIMARY

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 5
Special Notice
Posted: May 7, 2026
View
Version 4Viewing
Special Notice
Posted: May 7, 2026
Version 3
Special Notice
Posted: Apr 21, 2026
View
Version 2
Solicitation
Posted: Apr 2, 2026
View
Version 1
Pre-Solicitation
Posted: Apr 2, 2026
View