Quick Summary
The Department of the Air Force is conducting a Sources Sought for 355 CMS/MXMCE Receptacle and Installation Services at Davis-Monthan Air Force Base, AZ. This market research aims to identify qualified Women-Owned Small Businesses (WOSB) capable of providing and installing two specialized 60 Amp electrical receptacles. Responses will help the 355th Contracting Squadron determine industry capabilities for a potential future solicitation. Responses are due February 17, 2026, at 12:00 PM MST.
Purpose & Scope
This is a Sources Sought announcement for market research purposes only. The 355th Contracting Squadron seeks to identify interested and capable contractors for the commodity purchase and installation of two 115/230VAC, 4-wire, 3-phase, 60 Amp receptacles. These receptacles must be designed to mate with the purge unit plug CPH-6034BC. The scope includes:
- Installation of two 115/230 VAC, 4-wire, 3-phase, 60-amp receptacles in Building 5045 at Davis-Monthan Air Force Base, AZ.
- Receptacles must be wall-mounted, compatible with Purge Unit Plug, Cat No. CPH-6034BC, and rated for Hazardous Location Class I, Group C, with delayed-action contacts.
- Removal and proper disposal of damaged or improper connectors.
- Ensuring installation does not interfere with existing equipment.
- Providing all necessary components for a complete and functional installation.
- Performing functional testing upon completion.
- Submitting shop drawings or specification sheets for receptacle compatibility and a schedule within 7 days of material receipt.
Required Product Specifications
The receptacles must meet the following salient characteristics:
- Dimensions: 15.75 in x 7 in x 5.63 in
- Electrical Requirement: 3P 4W Circuit - 115/230VAC At 60Hz
- Temperature Range: Class I, Divisions 1 & 2, Groups C, D; Class I, Zones 1 & 2, Groups IIB, IIA
- Features: Aluminum 60 Amp Receptacles With Feed-Thru Enclosures - 3W 4P Circuit - 115/230VAC At 60Hz - Hub Size 1-1/4 Inch.
Performance Requirements
- Installation must adhere to manufacturer's specifications, industry standards, and business practices.
- Work areas must be kept clean and safe.
- No asbestos-containing materials are permitted.
- Contractor employees must be certified, qualified, fluent in English, and comply with all base access, safety (OSHA), and security regulations (e.g., CUI, no weapons).
- Project completion is expected within 7 days after receiving all materials/parts.
Contract & Timeline
- Type: Sources Sought (Market Research)
- Set-Aside: Women-Owned Small Business (WOSB) Program Set-Aside (FAR 19.15)
- NAICS: 335932 - Noncurrent Carrying Wiring Device Manufacturing
- Response Due: February 17, 2026, at 12:00 PM Mountain Standard Time (MST)
- Published: February 10, 2026
Submission & Contact
Interested and capable contractors should submit feedback responses electronically to Mr. Jeffrey Dreyer at jeffrey.dreyer@us.af.mil. Proprietary information should be clearly marked. This is not a commitment by the Government, and no payment will be made for information submitted.