Replace Boiler in Building 221

SOL #: FA671226Q0001Combined Synopsis/Solicitation

Overview

Buyer

DEPT OF DEFENSE
Dept Of The Air Force
FA6712 911 AW LGC
CORAOPOLIS, PA, 15108-4495, United States

Place of Performance

Place of performance not available

NAICS

Plumbing (238220)

PSC

Maintenance, Repair And Rebuilding Of Equipment: Plumbing, Heating, And Waste Disposal Equipment (J045)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Feb 25, 2026
2
Last Updated
Mar 12, 2026
3
Submission Deadline
Mar 25, 2026, 3:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The 911th Airlift Wing, Air Reserve Station (ARS) is soliciting quotes for the replacement of the boiler system in Building 221 in Coraopolis, PA. This project involves removing an existing boiler and installing a new two-boiler redundant system, including temporary heating. This is a 100% Small Business Set-Aside opportunity, with an estimated construction magnitude between $250,000 and $500,000. Quotes are due March 25, 2026.

Scope of Work

The project entails the removal of the current boiler in Building 221 and its replacement with a redundant two-boiler system. Key tasks include replacing all hydronic piping, associated equipment, and insulation in the mechanical room. The existing flue will be demolished and replaced to ensure compatibility with the new boilers. Contractors must also disconnect existing gas piping, power, and control wiring, and install new or replacement components for these systems. Modification of the concrete pad to accommodate the new boilers is also required.

Additionally, the contractor must provide and operate a temporary heating system capable of maintaining a minimum temperature of 69 degrees Fahrenheit within the building during the boiler changeover. This includes supplying all necessary fuel and monitoring the system daily for proper operation and safety.

Contract & Timeline

  • Type: Request for Quote (RFQ) leading to a Firm-Fixed Price (FFP) contract
  • Set-Aside: 100% Small Business Set-Aside (FAR 19.5)
  • NAICS: 238220 (Plumbing, Heating, and Air-Conditioning Contractors) with a $19 Million size standard
  • Magnitude: Estimated between $250,000 and $500,000
  • Response Due: March 25, 2026, at 3:00 PM Z
  • Published: March 12, 2026

Site Visit

An organized site visit will be held at the project location; details are in the solicitation. Pre-registration is required, and attendance is limited to two representatives per company. While not mandatory for offer submission, failure to attend will not mitigate the contractor's responsibility to comply with all terms and specifications.

Additional Notes

Interested vendors must be registered and maintain an active registration in the System for Award Management (SAM) to submit an offer. All terms and conditions are in the solicitation documents, and vendors are responsible for monitoring the website for any amendments. No paper solicitation will be available.

People

Points of Contact

Files

Files

View
View
View
View

Versions

Version 3
Combined Synopsis/Solicitation
Posted: Mar 12, 2026
View
Version 2Viewing
Combined Synopsis/Solicitation
Posted: Mar 12, 2026
Version 1
Combined Synopsis/Solicitation
Posted: Feb 25, 2026
View
Amend - Replace Boiler in Building 221 | GovScope