Z1DA--NRM| 503-21-102 Correct FCA Electrical Deficiencies Phase 1 (VA-26-00004932)

SOL #: 36C24426R0017Solicitation

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
244-NETWORK CONTRACT OFFICE 4 (36C244)
PITTSBURGH, PA, 15215, United States

Place of Performance

Place of performance not available

NAICS

Commercial and Institutional Building Construction (236220)

PSC

Maintenance Of Hospitals And Infirmaries (Z1DA)

Set Aside

No set aside specified

Timeline

1
Posted
Dec 31, 2025
2
Last Updated
Feb 17, 2026
3
Submission Deadline
Feb 18, 2026, 9:30 AM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VISN 04) is soliciting proposals for a firm-fixed-price construction contract to correct electrical deficiencies at the James E. Van Zandt VA Medical Center in Altoona, PA. This project, identified as Phase 1 of the Facility Condition Assessment (FCA) corrections, involves significant infrastructure upgrades to the campus power system. Proposals are due February 18, 2026.

Scope of Work

The contractor shall provide all labor, materials, and supervision to:

  • Construct a new medium-voltage switchgear building.
  • Replace the campus 15KV switchgear.
  • Segregate the Building 1 essential electrical system.
  • Rectify distribution equipment with inadequate short-circuit ratings and working clearances.
  • Integrate specialized systems including fire alarms, HVAC controls, and security cameras.

Contract & Timeline

  • Type: Firm Fixed-Price
  • Magnitude: Between $5,000,000 and $10,000,000
  • Duration: 18 months from Notice to Proceed (updated via Amendment 1)
  • Set-Aside: Small Business
  • Response Due: February 18, 2026, 4:30 PM EST

Evaluation

Award will be made using a Best Value Tradeoff process. Technical Capability (Qualifications, Key Subcontractors, and Project Execution) and Past Performance are of equal weight and, when combined, are significantly more important than price.

Additional Notes

This project includes several sole-source requirements to maintain facility standards, including SALTO door hardware, Honeywell Notifier fire alarms, Trane Tracer Ensemble BAS controls, and Avigilon security cameras. Bidders must account for liquidated damages of $582.98 per day for inexcusable delays. A bid guarantee of 20% is required with the proposal.

People

Points of Contact

Kaitlyn V SzlachtaContract SpecialistPRIMARY

Files

Files

Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download
Download

Versions

Version 6
Solicitation
Posted: Feb 17, 2026
View
Version 5Viewing
Solicitation
Posted: Feb 6, 2026
Version 4
Solicitation
Posted: Jan 20, 2026
View
Version 3
Solicitation
Posted: Jan 16, 2026
View
Version 2
Solicitation
Posted: Jan 16, 2026
View
Version 1
Pre-Solicitation
Posted: Dec 31, 2025
View
Z1DA--NRM| 503-21-102 Correct FCA Electrical Deficiencies Phase 1 (VA-26-00004932) | GovScope