Emergency Repair Oxygen Supply Lines - 23Z5AJ2

SOL #: 15B50526Q00000005Solicitation

Overview

Buyer

Justice
Federal Prison System / Bureau Of Prisons
FMC CARSWELL
FORT WORTH, TX, 76127, United States

Place of Performance

Naval Air Station JRB, TX

NAICS

Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance (811310)

PSC

Medical Gases (6835)

Set Aside

Total Small Business Set-Aside (FAR 19.5) (SBA)

Timeline

1
Posted
Dec 22, 2025
2
Last Updated
Feb 13, 2026
3
Submission Deadline
Jan 27, 2026, 9:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Federal Bureau of Prisons (FBOP), specifically FMC Carswell in Fort Worth, Texas, is soliciting proposals for a Firm Fixed-Price contract for Emergency Repair Oxygen Supply Lines - 23Z5AJ2. This project primarily involves the installation of new master alarm panels and related components for oxygen supply lines. This opportunity is a Total Small Business Set-Aside. Proposals are due by January 27, 2026, at 3:00 PM CST.

Scope of Work

The project requires the provision of all necessary equipment, labor, materials, and incidentals to repair oxygen supply lines and related components at FMC Carswell, a federal prison for female inmates. Key aspects clarified through amendments indicate the primary focus includes:

  • Installation of new master alarm panels (not retrofitted) in the basement and 4th floor, requiring Infection Control Risk Assessment (ICRA) and Temporary Barrier Protection (T/B/P).
  • No digging is required for the work.
  • Four alarm connection points are to be installed on both master alarm panels to allow temporary supply monitoring, as required by NFPA 99 2024 5.1.3.5.12.2(8).
  • The 2" Oxygen riser is accessible in a chase, not requiring drywall access for ICRA barriers.
  • No outages will be scheduled as there is currently no oxygen being fed to the fourth floor.

Contract & Timeline

  • Contract Type: Firm Fixed-Price
  • Period of Performance: Delivery estimated by May 31, 2026.
  • Set-Aside: Total Small Business Set-Aside (FAR 19.5)
  • NAICS Code: 811310, with a small business size standard of $12.5 million.
  • Questions Due: January 26, 2026.
  • Proposal Due: January 27, 2026, at 3:00 PM CST.
  • Published Date: January 23, 2026 (latest amendment).

Evaluation & Submission

  • Evaluation Factors: Past Performance, Price, and Technical factors will be considered.
  • Submission Instructions: Interested quoters must be registered in www.sam.gov. Submit the SF-1449 form to the point of contact listed. Offerors must acknowledge receipt of all amendments.
  • Compliance: This solicitation is subject to the Federal IT Acquisition Reform Act (FITARA) approval process for the Master Alarm Panel specified in Section B of the Statement of Work.

Contact Information

  • Primary Contact: Angel R. Rivera Martinez
  • Email: a3rivera@bop.gov
  • Phone: 817-782-4107

People

Points of Contact

Angel R. Rivera MartinezPRIMARY

Files

Files

Download
Download
Download
Download
Download

Versions

Version 6
Solicitation
Posted: Feb 13, 2026
View
Version 5
Solicitation
Posted: Jan 27, 2026
View
Version 4Viewing
Solicitation
Posted: Jan 23, 2026
Version 3
Solicitation
Posted: Jan 16, 2026
View
Version 2
Solicitation
Posted: Jan 12, 2026
View
Version 1
Solicitation
Posted: Dec 22, 2025
View