W912C326 Combined synopsis/solicitation for Architect-Engineer (A-E) services
SOL #: W912C326RA007Combined Synopsis/Solicitation
Overview
Buyer
DEPT OF DEFENSE
Dept Of The Army
W6QM MICC-FORT BUCHANAN (RC)
FORT BUCHANAN, PR, 00934-4572, United States
Place of Performance
Place of performance not available
NAICS
Engineering Services (541330)
PSC
Other Architect And Engineering Services (C219)
Set Aside
Total Small Business Set-Aside (FAR 19.5) (SBA)
Original Source
Timeline
1
Posted
Mar 24, 2026
2
Submission Deadline
Apr 17, 2026, 12:00 PM
Qualification Details
Fit reasons
- NAICS alignment with historical contract wins in similar service areas.
- Scope strongly matches core technical capabilities and delivery model.
Risks
- Past performance thresholds may require one additional teaming partner.
- Potential clarification needed on staffing minimums before bid/no-bid.
Next steps
Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.
Quick Summary
The Department of the Army, MICC-Fort Buchanan (RC) is soliciting Architect-Engineer (A-E) services for a comprehensive structural and optional mechanical (HVAC) assessment of the Rodriguez Army Health Clinic in Fort Buchanan, Puerto Rico. This is a Total Small Business Set-aside opportunity, with the intent to award a Firm-Fixed-Price (FFP) contract. Proposals are due April 17, 2026, at 8:00 AM EST.
Scope of Work
The contractor will provide professional engineering services for a single-story, approximately 12,000 square foot clinic facility.
- Base Requirement (Structural Assessment): Conduct a complete non-invasive structural assessment of the building's components (foundation, walls, beams, floor, roof) to evaluate integrity, identify deficiencies, and provide a report with a prioritized list of recommended repairs and estimated costs. This includes reviewing available construction documents.
- Optional Requirement (Mechanical/HVAC Assessment): If exercised by the government, this involves a complete non-invasive inspection of the HVAC system, evaluating its condition and performance. An engineering analysis based on ACCA Manuals N, S, and D will determine if equipment and ductwork are correctly sized. A separate report with prioritized recommendations and cost estimates will be required.
- Deliverables: Draft and Final Structural Assessment Reports, Draft and Final Mechanical (HVAC) Assessment Reports (if option exercised), and a Stakeholder Briefing summarizing findings and recommendations.
Contract Details
- Contract Type: Firm-Fixed-Price (FFP)
- Set-Aside: Total Small Business Set-aside (FAR 19.5)
- NAICS Code: 541330 – Engineering Services (Size Standard: $12.5 million)
- PSC Code: C219 – Other Architect And Engineering Services
Submission & Evaluation
- Submission Method: 100% paperless, electronic submission via the Procurement Integrated Enterprise Environment (PIEE) Solicitation Module.
- Questions Due: April 03, 2026, 5:00 PM Eastern Standard Time
- Proposals Due: April 17, 2026, 8:00 AM Eastern Standard Time
- Selection Process: Based on demonstrated competence and qualifications using SF 330 submissions. Evaluation criteria include: Specialized Experience and Technical Competence, Professional Qualifications of Key Personnel, Past Performance, and Capacity to Accomplish the Work.
- Mandatory Prerequisite: Firms must hold a current, active license to practice engineering in Puerto Rico.
Contact Information
- Primary: Aheisha Crooks (aheisha.m.crooks.civ@army.mil)
- Secondary: Harvey Odom (harvey.odom.civ@army.mil)
People
Points of Contact
AHEISHA CROOKSPRIMARY
HARVEY ODOMSECONDARY
Files
Versions
Version 1Viewing
Combined Synopsis/Solicitation
Posted: Mar 24, 2026