H261--TRIENNIAL ELECTRICAL TESTING

SOL #: 36C25926Q0348Combined Synopsis/Solicitation

Overview

Buyer

Veterans Affairs
Veterans Affairs, Department Of
NETWORK CONTRACT OFFICE 19 (36C259)
Greenwood Village, CO, 80111, United States

Place of Performance

Aurora

NAICS

Building Inspection Services (541350)

PSC

Equipment And Materials Testing: Electric Wire, And Power And Distribution Equipment (H261)

Set Aside

Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14) (SDVOSBC)

Timeline

1
Posted
Apr 14, 2026
2
Last Updated
May 28, 2026
3
Submission Deadline
May 19, 2026, 10:00 PM

Qualification Details

Fit reasons
  • NAICS alignment with historical contract wins in similar service areas.
  • Scope strongly matches core technical capabilities and delivery model.
Risks
  • Past performance thresholds may require one additional teaming partner.
  • Potential clarification needed on staffing minimums before bid/no-bid.
Next steps

Validate eligibility requirements, assign capture owner, and schedule partner outreach to confirm teaming strategy before submission planning.

Quick Summary

The Department of Veterans Affairs (VA), Network Contract Office 19, is soliciting proposals for Triennial Electrical Testing services for the Eastern Colorado VA Healthcare System at the Rocky Mountain Regional VAMC in Aurora, CO. This requirement covers comprehensive testing, maintenance, certification, and repair of critical electrical systems. This is a Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside. Proposals are due May 19, 2026, at 4:00 PM Mountain Time.

Scope of Work

The contractor shall provide triennial testing, full maintenance, preventive maintenance, certification, and repair services for various electrical equipment and systems. This includes:

  • Generator Paralleling Switchgear and Control (PSG & ATO)
  • Automatic & Manual Transfer Switches (ATS/MTS), including Fire Pump ATS
  • Switchgear and Switchboard Assemblies
  • Medium Voltage Vacuum Circuit Breakers
  • Substation Transformers (Dry Type and Oil Filled)
  • Low Voltage Circuit Breakers (480 VAC)
  • Protective Relay Calibration (Solid State/Digital)
  • GE Multilin 750 relays
  • Metering and Instrumentation
  • Batteries for UPS systems
  • Electrical Vault Inspections (CLIN 0013)
  • Protective Relay Calibration Study (CLIN 0014)

Services encompass visual inspections, operational tests, measurements, cleaning, lubrication, calibration, and minor repairs. A final engineering appraisal report is required upon completion.

Contract Details

  • Contract Type: Firm-Fixed-Price
  • Set-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB). Offerors must be verified in the SBA Small Business Certification (SBS) database.
  • NAICS Code: 541350 (Building Inspection Services), Size Standard: $11.5 Million.
  • Place of Performance: Rocky Mountain Regional VA Medical Center, 1700 N. Wheeling St., Aurora, CO 80045.
  • Key Clauses: Includes Clause 52.222-90, "Addressing DEI Discrimination by Federal Contractors (APR 2026)".
  • Performance Standards: Compliance with manufacturer specifications, industry standards (NFPA-110, NFPA-70, NFPA-70B, NFPA-70E, NFPA 99, 29 CFR 1910), and VHA Directive 1028. A six-month limited warranty on repairs is required.

Submission & Evaluation

  • Submission Method: Email quotes only to Noaa Lanotte at noaa.lanotte@va.gov. Email size limit is 4MB.
  • Evaluation Factors:
    1. Technical capability or quality (most important)
    2. Price
    3. Past Performance (least important)
  • Award will be made on an All or Nothing Basis.
  • Offerors must submit quotes in four volumes: Technical Capability, Price, Past Performance, and VAAR 852.219-75 Certificate of Compliance.
  • Receipt of Amendment 0002 must be confirmed in the proposal.

Key Dates & Contacts

  • Proposal Due Date: May 19, 2026, 4:00 PM Mountain Time, Denver, USA.
  • Point of Contact: Noaa Lanotte, Contracting Officer, noaa.lanotte@va.gov, 303-712-5739.

Special Requirements

Contractor personnel must be qualified, licensed, and certified (e.g., NETA, OSHA 10/30). A site-specific safety plan and Lock-Out Tag-Out (LOTO) procedures are mandatory. Work is generally during normal business hours, with after-hours work for power shutdowns. A Wage Determination (2015-5419, Revision No. 31) is applicable, outlining minimum wage rates and fringe benefits for service employees.

People

Points of Contact

Noaa LanotteContracting OfficerPRIMARY

Files

Files

Download
Download
Download
Download
Download
Download

Versions

Version 7
Combined Synopsis/Solicitation
Posted: May 28, 2026
View
Version 6
Combined Synopsis/Solicitation
Posted: May 20, 2026
View
Version 5
Combined Synopsis/Solicitation
Posted: May 15, 2026
View
Version 4Viewing
Combined Synopsis/Solicitation
Posted: May 13, 2026
Version 3
Combined Synopsis/Solicitation
Posted: May 8, 2026
View
Version 2
Combined Synopsis/Solicitation
Posted: Apr 27, 2026
View
Version 1
Combined Synopsis/Solicitation
Posted: Apr 14, 2026
View